OPERATING MANUAL
8.2.4

HYDRAULIC STAGE MAINTENANCE

Dismount the device onto a frame as shown in the picture and turn it upside down.
Observe the fi ll level marking (X) on the oil tank.
8.2.5

CHECKING THE OIL LEVEL

1
Start up the pump for a short time without any product.
2
Then read oil level A.
Dismount the device onto a frame as shown in the picture and
turn it upside down.
Observe the fi ll level marking (X) on the oil tank.
Oil level A in the oil tank (1) has to be within the specifi ed
markings (X).
If the level deviates from these markings, the hydraulic oil must be
topped up.
Procedure:
1
Unscrew and remove threaded plug (5).
2
Top up oil to level A = middle of marking X.
3
Start up the pump for a short time without any product and check for air bubbles.
4
Screw in threaded plug (5) and tighten with 2 Nm; 1.5 lbft.
Using hydraulic oil
Using the wrong hydraulic oil can cause a malfunction.
Use only original hydraulic oil - Wagner Order No. 322912 (250 ml or 15 cu inch).
ORDER NUMBER DOC2340851