UNOCODE PRO
Press ENTER, the display will show:
- Fit the test key blank (Z3 template) into side A of the left-hand clamp
(Stop 0).
Fig. 27
- Lower the safety shield and press START. When cutting is complete
the display will show:
- Fit the test key (Z3 template) cut and carefully cleaned into side A of
the right-hand clamp (Stop 0).
Fig. 28
- Lower the safety shield and press START. When reading is complete
the display will show:
- Raise the safety shield, remove the Z3 template from the right-hand
clamp and replace with a carefully cleaned Z20 template (Stop 0).
Fig. 29
- Lower the safety shield and press START.
- After an intermediate message "Reading template measurements"
the display will show:
• Press ENTER to confirm the data.
• Press STOP to exit without confirming.
Note: acceptable value range: +/- 40 hundredths of a
millimetre.
Press ENTER, the display will show:
48
Copyright Silca 2017
Operating manual - English
Need help?
Do you have a question about the Unocode PRO and is the answer not in the manual?
Questions and answers