F2
• Press F2 to view any manual adjustments set up by the PC program.
Press ENTER to continue, the display will show:
F1
• Press F1 to view the cutting method set up by Silca for the card in question.
1
F2
2
• Press F2 to enable or disable the electrical contact function for reading the key blank measurements.
1 - A red "X" on the electrical contact icon means that it has been disabled.
2 - The symbol (*) in the clamp field means that the key will be cut reading the key blank measurements by electrical
contact.
Note: some cutting cards do not include electrical contact. In such cases the software does not allow editing.
Note: when electrical contact is used it is advisable to set key blank measurements that are the same
as those of the key to be cut.