6-2-2 Selection of contactor

Select the contactor selection current that is calculated from the rated output and the nominal input voltage of the
drive unit as in the expression below. And then select the contactor whose conventional free-air thermal current
meets the contactor selection current.
Contactor selection current [A]=
(Contactor selection current for 200V input [A] / Nominal input voltage [V]) × 200 [V]
Unit type
MDS-D-SVJ3-
Rated output
Contactor selection
current for 200V input
Selection example of contactor
(Mitsubishi Electric Corp.)
Conventional freeair thermal
current of the selection example of
contactor
Unit type
MDS-D-SPJ3-
Rated output
Contactor selection
current for 200V input
Selection example of contactor
(Mitsubishi Electric Corp.)
Conventional freeair thermal
current of the selection example of
contactor
Option part: A contactor is not prepared as an NC unit accessory, so purchase the part from your dealer, etc.
1. Use an alternating contactor.
POINT
2. Select a contactor whose excitation coil does not operate at 15mA or less.
Selection of contactor for 200V input
03NA
04NA
07NA
0.3kW
0.4kW
0.75kW
2.5A
5A
S-N12
S-N12
S-N12
-AC200V
-AC200V
-AC200V
20A
20A
075NA
22NA
37NA
0.75kW
2.2kW
3.7kW
6A
9A
S-N12-
S-N18-
S-N20-
AC200V
AC200V
AC200V
20A
25A
MDS-D-SVJ3/SPJ3 Series Specifications Manual
6-2 Selection of circuit protector and contactor
10NA
20NA
1.0kW
2.0kW
7A
8A
10A
S-N12
S-N18
-AC200V
-AC200V
20A
20A
25A
55NA
75NA
5.5kW
7.5kW
15A
23A
31A
S-N25-
S-N25-
AC200V
AC200V
32A
50A
50A
35NA
3.5kW
15A
S-N20
-AC200V
32A
110NA
11kW
45A
S-N35-
AC200V
60A
6 - 5