4-2 Spindle motor

4-2-1 Environmental conditions
Environment
Ambient temperature
Ambient humidity
Storage temperature
Storage humidity
Atmosphere
Altitude
4-2-2 Shaft characteristics
There is a limit to the load that can be applied on the motor shaft. Make sure that the load applied on the
radial direction, when mounted on the machine, is below the tolerable values given below. These loads may
affect the motor output torque, so consider them when designing the machine.
SJ-VL2.2ZT
SJ-VL11-10FZT
SJ-VL0.75-01T, SJ-VL1.5-01T
SJ-D3.7/100-01, SJ-DJ5.5/100-01
SJ-V2.2-01T, SJ-V3.7-01T, SJ-V5.5-01ZT, SJ-V7.5-01ZT, SJ-V7.5-03ZT,
SJ-VL11-05FZT-S01, SJ-VL11-07ZT,
SJ-D5.5/100-01, SJ-DJ7.5/100-01
SJ-D7.5/100-01, SJ-D11/80-01, SJ-DJ11/100-01
SJ-V11-01ZT
CAUTION
Consider on the machine side so that the thrust loads are not applied to the spindle motor.
0°C to +40°C (with no freezing)
90% RH or less (with no dew condensation)
-20°C to +65°C(with no freezing)
90% RH or less (with no dew condensation)
Indoors (no direct sunlight);
no corrosive gas, inflammable gas, oil mist or dust
Operation/storage: 1000m or less above sea level
Transportation: 10000m or less above sea level
Spindle motor
(Note) The load point is at the one-half of the shaft length.
MDS-D-SVJ3/SPJ3 Series Specifications Manual
Conditions
Tolerable radial load
196N
245N
490N
980N
1470N
1960N
Radial load