Appendix 1-2-2 Optical Communication Repeater Unit Cable - Mitsubishi Electric MDS-D-SPJ3 Specification Manual

Table of Contents

Advertisement

When DG24 cable is used, proximity switch or external emergency stop cannot be wired, so these
CAUTION
functions cannot be used.

Appendix 1-2-2 Optical communication repeater unit cable

< F070 cable connection diagram >
24VDC power side terminal
Crimping Terminal : V1.25-3 or V1.25-4 × 2
< F110 cable connection diagram >
24VDC power side connector
Connector : 3-178127-6
Contact : 1-175218-5 (for AWG16 ) × 3
1-175217-5 (for AWG22 ) × 2
(J.S.T.)
0V
24VDC
(Tyco Electronics)
DCOUT
+24V
1B
0V
2B
FG
3B
ACFAIL
1A
0V
2A
MDS-D-SVJ3/SPJ3 Series Specifications Manual
Appendix 1-2 Cable connection diagram
Optical communication repeater unit side
connector
(Tyco Electronics)
Connector : 2-178288-3
Contact : 1-175218-5 × 3
FG
3
2
0V
1
24VDC
DCIN
Optical communication repeater unit side
connector
(Tyco Electronics)
<DCIN>
Connector : 2-178288-3
Conntact : 1-175218-5 × 3
<ACFAIL (CF01)>
51030-0230
50084-8160 × 2
DCIN
AWG16
1
+24V
0V
2
3
FG
CF01
AWG22
ACFAIL
2
1
0V
Appendix 1 - 5