Mitsubishi Electric MDS-D-SPJ3 Specification Manual page 58

Table of Contents

Advertisement

< HF Series >
[ HF75 ]
10
7.5
5
Short time operation range
2.5
Continuous operation range
0
0
2000
Rotation speed [r/min]
[ HF54 ]
15
12
9
Short time operation range
6
3
Continuous operation range
0
0
1000
2000
Rotation speed [r/min]
[ HF224 ]
50
40
30
Short time operation range
20
10
Continuous operation range
0
0
1000
2000
Rotation speed [r/min]
[ HF223 ]
40
30
Short time operation range
20
10
Continuous
operation range
0
0
1000
2000
Rotation speed [r/min]
(Note)
The above graphs show the data when applied the input voltage of 200VAC. When the input
voltage is 200VAC or less, the short time operation range is limited.
[ HF105 ]
12
9
6
Short time operation range
3
Continuous operation range
0
4000
0
Rotation speed [r/min]
[ HF104 ]
25
20
15
Short time operation range
10
5
Continuous operation range
0
3000
0
1000
Rotation speed [r/min]
[ HF204 ]
50
40
30
Short time operation range
20
10
Continuous operation range
0
3000
0
1000
Rotation speed [r/min]
[ HF303 ]
80
60
40
Short time operation range
20
0
0
Rotation speed [r/min]
MDS-D-SVJ3/SPJ3 Series Specifications Manual
2000
4000
50
40
30
20
10
0
2000
3000
20
15
10
2000
3000
Continuous
operation range
1000
2000
2-3 Tool spindle motor
[ HF154 ]
Short time operation range
Continuous operation range
0
1000
2000
3000
Rotation speed [r/min]
[ HF123 ]
Short time operation range
5
Continuous
operation range
0
0
1000
2000
Rotation speed [r/min]
2 - 19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mds-d-svj3

Table of Contents