Selection Of Wire - Mitsubishi Electric MDS-D-SPJ3 Specification Manual

Table of Contents

Advertisement

(3) 600V bridge polyethylene insulated wire (IC) 105 °C product
(Example according to JEAC8001)
Terminal name
Unit type
MDS-D-SPJ3-075NA
MDS-D-SPJ3-22NA
Spindle
MDS-D-SPJ3-37NA
drive
MDS-D-SPJ3-55NA
unit
MDS-D-SPJ3-75NA
MDS-D-SPJ3-110NA
MDS-D-SVJ3-03NA
MDS-D-SVJ3-04NA
Servo
MDS-D-SVJ3-07NA
drive
MDS-D-SVJ3-10NA
unit
MDS-D-SVJ3-20NA
MDS-D-SVJ3-35NA
1. Selection conditions follow IEC/EN60204-1, UL508C, JEAC8001.
- Ambient temperature is maximum 40°C.
- Cable installed on walls without ducts or conduits.
To use the wire under conditions other than above, check the standards you are supposed to
CAUTION
follow.
2. The maximum wiring length to the motor is 30m.
If the wiring distance between the drive unit and motor is 20m or longer, use a thick wire so that the
cable voltage drop is 2% or less.
3. Always wire the grounding wire.
CNP1
CNP2
(L11, L21)
(L1, L2, L3,
)
2
2
AWG
AWG
mm
mm
2
14
2
14
2
14
1.25
2
14
3.5
12
5.5
10
2
14
2
14
2
14
1.25
2
14
2
14
2
14
MDS-D-SVJ3/SPJ3 Series Specifications Manual
CNP3
(U, V, W,
)
2
AWG
mm
mm
2
14
2
14
2
14
16
3.5
12
3.5
10
3.5
5.5
10
2
14
2
14
2
14
16
2
14
2
14
3.5
12

6-1 Selection of wire

CNP2
Magnetic
(P,C)
brake
2
2
AWG
AWG
mm
2
14
---
---
12
2
14
1.25
16
6 - 3