MITSUBISHI CNC
3 Function Specifications

3-5 Sequence functions

3-5-1 Contactor control function
With this function, the contactor ON/OFF command is output from the power supply unit (or servo/spindle
drive unit for integrated type) based on the judgement as to whether it is in emergency stop, emergency stop
cancel, spindle deceleration and stop or vertical axis drop prevention control, etc.
3-5-2 Motor brake control function
With this function, the brake ON/OFF command is output from the servo drive unit based on the judgement
as to whether it is in emergency stop, emergency stop cancel or vertical axis drop prevention/pull-up control,
etc.
When a multiaxis drive unit is connected, all the axes are simultaneously controlled.
3-5-3 External emergency stop function
Besides the emergency stop input from the NC, double-protection when an emergency stop occurs can be
provided by directly inputting an external emergency stop, which is a second emergency stop input, to the
power supply unit (servo/spindle drive unit for integrated type).
Even if the emergency stop is not input from NC for some reason, the contactors will be activated by the
external emergency stop input, and the power can be shut off.
(1)
When DICOM is connected to 24V
Emergency
stop
Mitsubishi NC
Alarm
OPT1
Optical
communication
EMG
G380 cable
Open collector
External power supply
is required for output.
External emergency
stop input
External emergency stop switch
*Emergency stop when opened.
*Operated synchronously on the NC
24G
side using another contact.
When DICOM is connected to 24G
(2)
Emergency
stop
Mitsubishi NC
Alarm
OPT1
Optical
communication
EMG
G380 cable
External emergency
stop input
24VDC
External emergency stop switch
*Emergency stop when opened.
*Operated synchronously on the NC
side using another contact.
3 - 18
MDS-D-SVJ3/SPJ3
Emergency
stop
Alarm
CN1A
CN1B
Optical
communication
G396 cable
CN9
Contactor
15
MC
shutoff
13
DO
command
3 DOCOM
24VDC
20 EMGX
19
DI
5 DICOM
(Note1) Make sure that DICOM is connected to 24V in all drive systems.
(Note2) Make sure that 24G is connected to the external emergency stop switch.
(Note3) Make sure that the contact of the external emergency stop switch is not
the same as NC.
Select the polarity of DICOM
MDS-D-SVJ3/SPJ3
Emergency
stop
Alarm
CN1A
CN1B
Optical
communication
G396 cable
CN9
Contactor
15
MC
shutoff
13
DO
command
3 DOCOM
20 EMGX
19
DI
5 DICOM
24G
(Note1) Make sure that DICOM is connected to 24G in all drive systems.
(Note2) Make sure that 24V is connected to the external emergency stop switch.
(Note3) Make sure that the contact of the external emergency stop switch is not
the same as NC.
MDS-D-SVJ3/SPJ3
CN1A
CN9
Contactor
15
MC
shutoff
13
DO
command
3 DOCOM
24VDC
20 EMGX
19
DI
5 DICOM
MDS-D-SVJ3/SPJ3
CN1A
CN9
Contactor
15
MC
shutoff
13
DO
command
3 DOCOM
20 EMGX
19
DI
5 DICOM
24G

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mds-d-svj3

Table of Contents