4.
P erf orm the p osition correction of the f eed direction (reduce horiz ontal strip es). (Sep arate setting "
M EM O
Feed direction means the feed direction of the media. Perform the correction adjusting to the media
in advance because horizontal stripes are more likely to occur during printing when the movement
distance of the media changes subtly depending on the media's type or thickness.
A
P ress [ ] to select " SET."
CALIBRATION
B
ress
to con rm our entr
The test pattern of feed correction is printed.
You can select "NEXT" and press [ENTER] to proceed to the next menu.
C
P ress [ ENTER] .
INPUT
D
V iew the p rinted test p attern, and then determine the correction values.
Select the value to make the gap and overlap between the upper/lower squares smallest. In the case
of the following gure, select "-0.40." When you cannot choose between two sequential numbers,
specify a value that is between them.
G a p p r e s e
E
P ress [ ] or [ ] to select the correction value.
CALIBRATION
0.00%
+0.40%
F
ress
to con rm our entr
= C u r r e n t c o
n t
r r e c t i o n v a
l u e
B asic P rinting Method
)
P . 12 2
O v e
r l a p
41