Section 3: Troubleshooting

3.4.2 Error Codes

If the status display window shows one of the codes in the Error Codes table you may need a Christie
accredited service technician to repair the component identified by the error code.
Error codes are displayed in a three phase format:
• First 2 digits represent the component or error category
• Second 2 digits represent the specific problem
• Display off
This cycle repeats. The LED will be red while the error code is displayed.
Acknowledge and clear the error by pressing Exit twice when at the presentation level (no OSD on the screen).
If the error recurs then try resetting the projector by powering OFF and ON again. Contact the dealer if the
problem persists or if you see a code not listed in the following table.
Table 3.2 Error Codes
ERROR CODE
Light Engine
LE
Link
LI
Projector Head Module (PHM) Fan
FP
Electronic Module (EM) Fan
FE
3-4
ITEM
01
Light engine link error
02
Light engine initialization error
03
Red LED Feedback Failure
04
Green LED Feedback Failure
05
Blue LED Feedback Failure
01
Error on EM network
02
Error on PHM network
03
Error on ArrayLOC link
01
PHM FD Fan 1 stalled
02
PHM FD Fan 2 stalled
03
PHM LMC Fan 1 stalled
04
PHM LMC Fan 2 stalled
01
EM Fan 1 stalled
02
EM Fan 2 stalled
DESCRIPTION
Entero RPMSP/RPMWU/RPMHD-LED01 Service Manual
020-100368-05 Rev. 1 (06-2012)