Error Codes

013-100149-02 Rev. 1 (01/07)
Code
Description
GENERAL
12
Software bug. Contact dealer/factory.
13
Flash memory corrupted. Download new software.
14
Engineering only programming is complete. Call Christie, replace TIPM.
15
Attempting to download code without being in boot mode
16
Invalid interrupt. Power off/on. If it persists, contact dealer/factory.
17
Forced boot mode. Keys held down too long.
18
Attempting to program boot mode without jumper
LAMP FAILURES
21
Lamp compartment too hot
25
Lamp 1 not installed
26
Lamp 1 Interlock: door open, lamp not installed
27
Unable to turn lamp 1 ON
28
Lamp 1 shut off unexpectedly
29
Lamp 1 driver overheated
2A
Lamp 1 driver operation error (e.g. too hot can't start)
2C
Lamp 1 driver UART communications failure
30
Lamp 2 not installed
31
Lamp 2 door open
32
Unable to turn lamp 2 ON (unknown reason)
33
Lamp 2 shut off unexpectedly
34
Lamp 2 driver overheated
35
Lamp 2 driver reports operation error (e.g. too hot can't start)
36
Lamp 2 driver UART communications failure
37
Lamp Watchdog Tripped – Unless lamps turn on again after 3 minutes, assume software hung.
POWER AND COOLING
41
Lamp 1 driver Vcc to low
42
Color wheel 1 stopped for at lease one second
44
Lamp 2 driver Vcc too low
45
Color wheel 2 stopped for at least one second
4C
Projector shutdown due to critical error
51
TIPM fan failed
53
Main blower failed
56
Engine fan failed
57
Lamp 1 driver fan failed
58
Lamp 1 fan failed
59
Lamp 2 driver fan failed
5A
Lamp 2 fan failed
TIPM (image processor)
60
Boot code CRC failed
61
Unable to program the DigMux PLD
62
Unable to program the Control PLD
63
Unable to program the BUBKS PLD
64
Unrecognized ROM type
65
Write to flash ROM failed
66
General image processor failure
67
Downloaded code will not fit in the ROMs
68
Communication problem with scaler on image processor
BUILT-IN or EEPROM
70
Unable to access the EEPROM on the built-in keypad
71
EEPROM memory re-initialization (built-in keypad)
72
Unable to access the EEPROM on the lamp module
73
Unable to access the EEPROM on the Back End Board
BACK END BOARD
80
Unable to detect Back End Board
81
Unable to program a device on the programming bus
82
TI flash download failure – not started
83
TI flash download failure – partial write
84
TI flash download failure – checksum read
85
TI – I2C write failure
86
Communications failure
BACKPLANE or OPTIONAL INTERFACE MODULE
A0
Unable to program the Option Card
A1
Unable to power the Option Card
A2
Unable to program the Backplane module
A3
Unable to program the Warp Module
Exit
Exit
Clear system errors with
again (wait at least 90 seconds and allow for proper cooling). For detailed information, monitor the RS232 IN port. Contact
dealer/factory if error persists and if a code appears that is not listed.