Error Codes - Christie DS+60 User Manual

Hide thumbs Also See for DS+60:
Table of Contents

Advertisement

'

Error Codes

Code
GENERAL
12
13
14
15
16
18
LAMP FAILURES
21
25
26
27
28
29
2A
2C
30
31
32
33
34
35
36
POWER AND COOLING
40
41
42
43
44
45
4C
51
53
56
57
58
59
5A
TIPM (image processor)
60
61
62
63
64
65
66
67
68
BUILT-IN or EEPROM
70
71
72
73
BACK END BOARD
80
81
82
83
84
85
86
BACKPLANE or OPTIONAL INTERFACE MODULE
A0
A1
A2
A3
Clear system errors with
again (wait at least 90 seconds and allow for proper cooling). For detailed information, monitor the RS232 IN port. Contact
dealer/factory if error persists and if a code appears that is not listed.
Description
Software bug. Contact dealer/factory.
Flash memory corrupted. Download new software.
Engineering-only programming is complete. Call Christie, replace TIPM.
Attempting to download code without being in boot mode
Invalid interrupt. Power off/on. If it persists, contact dealer/factory.
Attempting to program boot mode without jumper
Lamp compartment too hot
Lamp 1 not installed
Lamp 1 Interlock: door open, lamp not installed
Unable to turn lamp 1 ON
Lamp 1 shut off unexpectedly
Lamp 1 driver overheated
Lamp 1 driver operation error (e.g. too hot can't start)
Lamp 1 driver UART communications failure
Lamp 2 not installed
Lamp 2 door open
Unable to turn lamp 2 ON (unknown reason)
Lamp 2 shut off unexpectedly
Lamp 2 driver too hot
Lamp 2 driver reports operation error (e.g. too hot can't start)
Lamp 2 driver UART communications failure
Lamp 1 shutdown due to corresponding fan failure
Lamp 1 driver Vcc to low
Color wheel 1 stopped for at lease one second
Lamp 2 shutdown due to corresponding fan failure
Lamp driver Vcc too low
Color wheel 2 stopped for at least one second
Projector shutdown due to critical error
TIPM fan failed
Main blower failed
Engine fan failed
Lamp 1 driver fan failed
Lamp 1 fan failed
Lamp 2 driver fan failed
Lamp 2 fan failed
Boot code CRC failed
Unable to program the DigMux PLD
Unable to program the Control PLD
Unable to program the BUBKS PLD
Unrecognized ROM type
Write to flash ROM failed
General image processor failure
Downloaded code will not fit in the ROMs
Communication problem with scaler on image processor
Unable to access the EEPROM on the built-in keypad
EEPROM memory re-initialization (built-in keypad)
Unable to access the EEPROM on the lamp module
Unable to access the EEPROM on the Back End Board
Unable to detect Back End Board
Unable to program a device on the programming bus
TI flash download failure – not started
TI flash download failure – partial write
TI flash download failure – checksum read
TI – I2C write failure
Communications failure
Unable to program the Option Card
Unable to power the Option Card
Unable to program the Backplane module
Unable to program the Warp Module
Exit
Exit
. If you encounter a system error, try resetting the projector by powering it off and on
Section 3: Operation
Christie DS+60 User's Manual
3-59

Advertisement

Table of Contents
loading

Table of Contents