4 Adjustment
Adjust the ADJUSTING SCREW A until it makes contact
7
with the PLATE so that the clearance shown in the figure
will be 9.2—10.6 mm. (STANDARD : 9.7 mm)
4
Tighten SCREW B. Make sure that the PLATE is not
8
tilting.
Tighten SCREW C after setting the HEAD CARRIAGE so
9
that the RESIN part on the HEAD CARRIAGE makes
contact with the PLATE.
Try test printing. If there is twisted ribbon or broken ribbon,
10
readjust 7 by changing the amount.