Summary of Contents for Roland DXY_1350

  • Page 1 XY PLOTTER DXY-1350A DXY-1150A USER'S MANUAL Thank you very much for purchasing the DXY-1350A/1150A. • To ensure correct and safe usage with a full understanding of this product's performance, please be sure to read through this manual completely and store it in a safe location. •...
  • Page 2 The I/O cables between this equipment and the computing device must be shielded. ROLAND DG CORPORATION 1-6-4 Shinmiyakoda, Hamamatsu-shi, Shizuoka-ken, JAPAN 431-2103 MODEL NAME : See the MODEL given on the rating plate.
  • Page 3: Table Of Contents

    List of Optional Cables ..................... 38 List of Character Sets ....................39 Specification of DXY-1350A/1150A ................ 42 Windows is a registered trademark or trademark of Microsoft Corporation in the United States and/or other countries. Copyright © 1997 ROLAND DG CORPORATION...
  • Page 4: To Ensure Safe Use

    To Ensure Safe Use About Notices Used for instructions intended to alert the user to the risk of death or severe injury should the unit be used improperly. Used for instructions intended to alert the user to the risk of injury or material damage should the unit be used improperly.
  • Page 5 Do not injure or modify the Do not use with a damaged electrical power cord, nor power cord or a power outlet subject it to excessive bends, that is loose when the AC twists, pulls, binding, or pinch- adapter is plugged in. Use with any ing, nor place any object of other power...
  • Page 6: About The Labels Affixed To The Unit

    About the Labels Affixed to the Unit These labels are affixed to the body of this product. The following figure describes the location. Model name DXY-1350A DXY-1150A Rear Affixed to the 230 V/240 V adapter Rating label Use a rated power supply. In addition to the symbols, the symbols shown below are also used.
  • Page 7: Checking Accessories

    Checking Accessories The following accessories are packed together with the main unit. Before using, be sure to check to make sure that all accessories have been included. Stand x 2 ( L and R) Exclusive AC adapter x 1 Metal strip (DXY-1150A only ) x 3 Rubber positioning sticker Transparent positioning sticker Paper clip (DXY-1150A only ) x 1...
  • Page 8: Part Names And Functions

    Part Names and Functions Drawing board Pen stock Paper is mounted here. (The DXY-1350A use Pens are loaded here. Pen stand electrostatic adsorption, and the DXY-1150A is Pens can be stored here. equipped with a metal plate.) Control panel Used to make various settings and operate the DXY.
  • Page 9: Control Panel

    Control Panel REPLOT LED (DXY-1350A only) Lights up when replotting is possible. [REPLOT MODE] key (DXY-1350A only) Switches to the Replot mode. (See "Explanation of Functions and Operation".) [REPLOT] key (DXY-1350A only) Press this key while the REPLOT MODE LED is lit to execute replotting.
  • Page 10: Step-By-Step Plotting

    Step-by-Step Plotting Operation Flow When using the DXY, plotting is carried out using the sequence of steps described below. Refer to the pages indicated for each step for an explanation of how the operation is performed. Set up the plotter. Be sure to follow this proce- dure when using the DXY for the first time.
  • Page 11: Setting Up The Stands

    Setting Up the Stands Never install this unit in any of the following situations, as it could result in damage: • Do not install the unit on an unstable surface. • Places with excessive electrical noise. • Places with excessive humidity or dust. •...
  • Page 12: Connection

    Connection Before connecting the cable, make sure the computer's power and the DXY's power switch are switched off. Securely connect the power cord, computer I/O cable and so on so that they will not be unplugged and cause failure during operation. The arm and pen carriage move when the unit is switched on and while performing plotting --keep hands and objects away at these times.
  • Page 13: Loading The Paper

    Loading the Pens *For additional information on pen types (options), refer to "Pens". Load the pens only in the pen stock. Attempting to mount a pen directly in the pen carriage may cause faulty operation. Use only proprietary pens made exclusively for use with the DXY. Failure to do so may result in faulty operation because of differences in pen length.
  • Page 14 Remove bubbles and wrinkles from the paper by After positioning, turn on the [PAPER HOLD] wiping with a dry cloth. key to secure the paper to the drawing board. PAPER HOLD How to Load Paper on the DXY-1150A As shown in the figure, use the paper clip on the Remove bubbles and wrinkles from the paper, and left side of the unit to align the sheet of paper install the metal plate on the left side of the sheet.
  • Page 15: Self-Testing

    Self-testing The arm and pen carriage move when the unit is switched on and while performing plotting --keep hands and objects away at these times. Self-test Mode A self-test can be carried out to check whether the DXY is functioning correctly. When doing this, the plotter does not have to be connected to the computer.
  • Page 16: Downloading Plot Data

    Downloading Plot Data Plot data is sent from the host computer (the program) to the DXY and plotted out. Make the settings described below to match the program that you're using. This example describes the general values for output (plotting). If you need detailed information about output methods, please see the documentation for the software you're using.
  • Page 17 Settings for Communication Parameters Using a serial (RS-232C) cable to connect the DXY with the computer enables the Auto-Protocol function, which makes it unnecessary to set communication parameters on the DXY. About Auto Protocol Because the DXY can automatically determine communication parameters, plotting can be carried out simply by downloading the plot data from the computer.
  • Page 18: After Plotting

    After Plotting 1. Remove the paper. DXY-1350A: Press the [PAPER HOLD] key to release the electrostatic adsorption and remove the paper. DXY-1150A: Remove the paper clip, release the metal strips, and remove the paper. 2. Turn off the DXY. Switch off the power to the DXY. If the plotter will not be used for a long time, the electrical cord should also be unplugged.
  • Page 19: Explanation Of Functions And Operation

    Explanation of The DXY has a range of functions that can be performed using the keys on the control panel. This section describes how to Functions and use these functions. Operation < Replotting (DXY-1350A Only) > 1. Before downloading the plot data, press the [ REPLOT MODE ] key. The REPLOT MODE LED lights up.
  • Page 20: Pens

    This section describes the pens optionally available for use with the DXY, as well as the DXY's pen-related functions. Compatibil- Pens ity exists for pens and paper. Please refer to the information contained here to select combinations with good compatibility. By selecting optimum conditions for the pen and paper that are used, the DXY can achieve more accurate plots.
  • Page 21 Standard Ceramic Pen Plotting distance Pen cap rubber (with our standard paper) orientation 0.25 mm : 2000 m Features (0.00984":78740") 0.35 mm : 1300 m The pen tip is a ceramic tube, with ink flowing through it to (0.0138" :51181") form the line 0.50 mm : 700 m Because pen tip diameter is uniform, line thickness is uniform...
  • Page 22 Thick Water Based Fiber Tipped Pen Plotting distance Pen cap rubber (with our standard paper) orientation Features 2 mm : 100 m (1/16":3937") Thick water-based fiber tipped pen draws a 2 mm thick line Comes in eight colors (black, red, blue, green, orange, pink, Applicable paper brown, purple) High-quality paper, coated paper, tracing paper...
  • Page 23: Paper

    Oil on the paper surface may cause poor performance Take care when loading the paper to prevent transfer of oils or dirt from your hand to the paper surface. When using paper not supplied by Roland DG Corp., observe the following points in...
  • Page 24: Plotting Area

    Plotting Area The maximum size of the plotting area varies according to the selected instruction set and operation steps, even when using the same size of paper. For an explanation of how to load and position paper, see "Loading the Paper" on pages 8 and 9.
  • Page 25 RD-GL II t t e i t t i t t ± ± " 6 ) " ± ± " 2 ) " ± ± " 2 ) " ± ± " 6 ) " ± ± " 6 ) " ±...
  • Page 26: Dip Switches

    * DIP switches settings must be made only when the DIP Switches power is turned off. The DIP switches on the back of the main unit can be used in various combinations to enable a variety of plotting conditions. Please change these settings to match your needs. These are all set to OFF when the DXY-1350A/ 1150A is shipped from the factory.
  • Page 27 SW 1-6 Plot rotation When this switch is set to ON, the normal plot orientation is rotated 90°. When OFF When ON SW 1-7 Plotting speed This selects plotting speed. When shipped from the factory, this is set to [ NORMAL ], for a maximum plotting speed of 420 mm/sec in all directions.
  • Page 28: What To Do If

    What to Do If... If the DXY Doesn't Run... Is the DXY power on? Turn on the power. Is the DXY operating incorrectly Follow the procedure described under " Self-testing " to execute a self-test. If the self-test finds a problem, check to make sure that the problem is not due to the computer or the software.
  • Page 29 Plot quality is poor Is the paper of the recommended type? Refer to the chart shown in " Paper " and load a paper type that is suitable for the DXY. Is the paper loaded correctly? Read “ Loading the paper ”, and load the paper correctly. Do the pens match the paper type? Read “...
  • Page 30: List Of Dxy-Gl Related Instructions

    List of DXY-GL The list provides the instruction compatibility of the DXY-1350A/1150A with the DXY-GL I instruction Related Instructions system and the parameters of these instruction. : Compatible. : Ignored. : Incompatible. Instructions Compati- Format Parameter Range [Default value] bility Circle center A x,y Center coordinate...
  • Page 31: List Of Rd-Gl I Related Instructions

    List of RD-GL I The list provides the instruction compatibility of the DXY-1350A/1150A with the RD-GL I instruction Related Instructions system and the parameters of these instruction. : Compatible. : Ignored. : Incompatible. Instruction Compati- Format Parameter Range [Default value ] N o t e bility Arc Absolute...
  • Page 32 Instruction Compati- Format Parameter Range [Default value ] N o t e bility Output Commanded none Position none Output Digitize none Output Error Output Factor none 40,40[TERM] (10,10[TERM]: DX Y-GL 0.1mm mode) Output Hard-Clip Limits none none 1350(DXY-1350A) Output Identification 1150(DXY-1150A) none 0,1,0,0,1,0,0,0...
  • Page 33: List Of Rd-Gl Ii Related Instructions

    The list provides the instruction compatibility of the List of RD-GL II DXY-1350A/1150A with the RD-GL II instruction system and the parameters of these instruction. Related Instructions : Compatible. : Ignored. : Incompatible. * 1: - ( 2 )—( 2 * 2: - 0—...
  • Page 34 Instruc- Compati- Format Parameter Range ([ ]: Default) Expanation tion bility DT t; t: Label terminator [[ETX] (03h)] DV n; n: Character : 0 or 1 [0] direction (Decimal fractions are rounded) EA x,y; x,y: : *1 Absolute coordinate diagonal to rectangle EC n;...
  • Page 35 Instruc- Compati- Format Parameter Range ([ ]: Default) Expanation tion bility LO n; n: Position number : 1—9,11—19 (Decimal fractions are rounded) [1] LT n(,l); n: Pattern number : -6—+6 l: 1 pitch length : *2 (%) [4%] None None None X-axis and Y-axis coordinate values that are output are up to the forth decimal point and are real numbers within the *1 range.
  • Page 36 Instruc- Compati- Format Parameter Range ([ ]: Default) Expanation tion bility None SC Xmin,Xmax,Ymin Xmin,Ymin: User : *1 ,Ymax(,type(,left,bottom)); coordinate of P1 SC Xmin,Xfactor,Ymin Xmax,Ymax: User : *1 ,Yfactor,type; coordinate of P1 type: Scaling type : 0,1,2 left : 0—100 (%) bottom : 0—100 (%) Xfactor: User X...
  • Page 37: The Specifications Of The Interface

    Parallel Interface (in compli- The Specifications ance with specifications of of the Interface Centronics) Connector Serial Interface (RS-232C) Connector 3.3K ** = Device control Device control instructions are used to determine the communication sequence between the plotter and computer through RS-232C interface and/or tell the plotter the current computer state. Among them, some device control instructions set the output specifications of RD-GLI/II instructions.
  • Page 38 Instruction Format Parameter Range ([ ] is default) Explanation RD-GL I RD-GL II ESC .H [ESC].H<P1>;<P2>; P1:The number of bytes for 0-15358(byte) [80(byte)] When receiving the ENQ character set by <P2>, Sets ENQ/ACK <P3>;••••••••;<P12>: data block [0(Sets nothing)] compares the value set by <P1> and the remaining Handshake Mode1 P2:ENQ character [All 0(Sets nothing)]...
  • Page 39 Instruction Format Parameter Range ([ ] is default) Explanation RD-GL I RD-GL II ESC .E [ESC].E None Outputs an error code related to RS-232C interface Output RS-232C (see the table below), and clears the error simulta- Error Code neously. At the same time, the error being displayed is canceled.
  • Page 40: List Of Optional Cables

    List of Optional Cables The dashed and the dotted lines shown on the cable wiring diagram above are intended to show the wiring more clearly. They are no different from the solid lines.
  • Page 41: List Of Character Sets

    List of character sets RD-GL I...
  • Page 42 RD-GL II Character Set No. Fixed-Space Fixed-Space Variable-Space Character Arc Font Vector Font Arc Font ANSI ASCII (1) ANSI ASCII (2) French/German Scandinavian Spanish/Latin Special JIS ASCII Roman Katakana ISO I.R.V. Automatic backspace. Draws, at the current pen location, the symbols having codes 41-51 (hexadecimal) from character set numbers 5, 15, and 25.
  • Page 43 Character Set No. Variable-Space Fixed-Space Fixed-Space Character Vector Font Arc Font Arc Font ISO Swedish ISO Swedish Name ISO Norway (1) ISO German ISO French (1) ISO U.K. ISO Italian ISO Spanish ISO Portuguese ISO Norway (2) ISO French (2) Drafting Set...
  • Page 44: Specification Of Dxy-1350A/1150A

    Specification of DXY-1350A/1150A The specifications of hardware DXY-1350A DXY-1150A Feature Flatbed Plotter Max. plotting area X axis: 432 mm (17"), Y axis: 297 mm (11-11/16") (However, on the DXY-1150A no plotting can be done on the area under metal strips.) Media sizes ISO A3, A4, ANSI A, B Number of pens...
  • Page 45 Please be aware that any amount of the purchase price will not be refunded for return of this product as a single item, regardless of whether the package is opened or unopened.) The enclosed Roland product is a single user version.