Product Certifications
September 2016
Appendix B
Rev 1.3
European Directive Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 59
Ordinary Location Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 59
Installation drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 62
B.1 European Directive Information
A copy of the EU Declaration of Conformity can be found at
the end of the Quick Start Guide. The most recent revision
of the EU Declaration of Conformity can be found at
EmersonProcess.com/Rosemount.
B.2 Ordinary Location Certification
As standard, the transmitter has been examined and tested
to determine that the design meets the basic electrical,
mechanical, and fire protection requirements by a
nationally recognized test laboratory (NRTL) as accredited
by the Federal Occupational Safety and Health
Administration (OSHA).
B.2.1 North America
E5
US Explosionproof (XP) and Dust-Ignitionproof (DIP)
Certificate: 3012302
Standards: FM Class 3600 - 2011; FM Class 3615 -
2006; FM Class 3810 - 2005; NEMA 250 -
1991; ANSI/ISA-S12.0.01 - 1998;
ANSI/ISA-S12.22.01 - 1998;
ANSI/ISA-60079-0 - 2009;
Markings: Explosionproof for Class I, Division 1,
Groups B, C, and D; Flameproof for Class
1, Zone 1 AEx d IIC T5 (–40 °C to 85 °C);
Dust-ignition proof for Class II and Class III,
Division 1, Groups E, F, and G;
Temperature Code T5 (T
85 °C); Enclosure Type 4X; Conduit seal
not required.
I5
US Intrinsic Safety (IS), Nonincendive (NI)
Certificate: 3012302
Standards: FM Class 3600 - 2011; Class 3610 - 2010;
Class 3611 - 2004; NEMA 250 - 1991;
ANSI/ISA-S12.0.01 - 1998;
ANSI/ISA-S12.22.01 - 1998;
ANSI/ISA-60079-0 - 2009;
ANSI/ISA-60079-11 - 2009
Product Certifications
www.aotewell.com
Product Certifications
E6
= –40 °C to
amb
I6
sales@aotewell.com
00809-0100-4022, Rev GA
Markings: Intrinsically Safe for use in Class I, Division
1, Groups A, B, C, and D; Temperature
Code T4 (–50 °C to 70 °C); Intrinsically
Safe for use in Class I, Zone 0 AEx ia IIC T4
(–50 °C to 70 °C) in accordance with
control drawing 04620-5007;
Nonincendive for Class I, Division 2,
Groups A, B, C, and D when connected in
accordance with Rosemount drawing
04620-5007; Enclosure Type 4X
Canada Explosionproof and Division 2
Certificate: 1384913
Standards: CSA Std C22.2 No. 25-1966;
CSA Std C22.2 No. 30-M1986;
CAN/CSA-C22.2 No. 94-M91;
CSA Std C22.2 No. 142-M1987;
CAN/CSA-C22.2 No. 157-92;
CSA Std C22.2 No. 213-M1987;
CAN/CSA-E79- 0-95; CAN/CSA- E79-1-95;
CAN/CSA- E79-11-95;
ANSI/ISA No. 12.27.01-2011
Markings: Explosionproof for Class I, Division 1,
Groups B, C, and D; Dust-Ignitionproof for
Class II and Class III, Division 1, Groups E, F,
and G; Temperature Code T5 (–50 °C to
40 °C); Explosion-proof for Class 1, Zone 1
Ex d IIC T5 (–20 °C to 40 °C); Suitable for
Class I, Division 2, Groups A, B, C, and D
when installed per Rosemount drawing
04620-5005; Enclosure Type 4X; Conduit
seal not required
Canada Intrinsic Safety
Certificate: 1384913
Standards: CSA Std C22.2 No. 25-1966; CSA Std
C22.2 No. 30-M1986;
CAN/CSA-C22.2 No. 94-M91;
CSA Std C22.2 No. 142-M1987;
CAN/CSA-C22.2 No. 157-92;
CSA Std C22.2 No. 213-M1987;
CAN/CSA-E79- 0-95; CAN/CSA- E79-1-95;
CAN/CSA- E79-11-95;
ANSI/ISA No. 12.27.01-2011
Industry Automation
Reference Manual
59