Quick Start Guide
00825-0100-4803, Rev EG
October 2018
Rosemount
3051S and 3051SF Series
Flow Meter MultiVariable
Transmitters

Advertisement

Table of Contents
loading

Summary of Contents for Emerson Rosemount MultiVariable 3051S Series

  • Page 1 Quick Start Guide 00825-0100-4803, Rev EG October 2018 ™ Rosemount 3051S and 3051SF Series ™ Flow Meter MultiVariable Transmitters...
  • Page 2: Table Of Contents

    Rosemount 3051SFC, and Rosemount 3051SFP. It does not provide instructions for diagnostics, maintenance, service, or troubleshooting. Refer to the Rosemount 3051SMV Reference Manual more instruction.This document is also available electronically on Emerson.com/Rosemount. WARNING Explosions could result in death or serious injury.
  • Page 3: Mount The Transmitter

    October 2018 Quick Start Guide Mount the transmitter Liquid flow applications Procedure 1. Place taps to the side of the line. 2. Mount beside or below the taps. 3. Mount the transmitter so that the drain/vent valves are oriented upward. A.
  • Page 4 Quick Start Guide October 2018 Steam flow applications Procedure 1. Place taps to the side of the line. 2. Mount beside or below the taps. 3. Fill impulse lines with water. A. Direction of flow Mounting brackets Figure 1-1: Mounting Bracket – Coplanar Flange Panel mount Pipe mount Rosemount 3051SMV...
  • Page 5 Only use bolts ™ supplied with the transmitter or sold by Emerson as spare parts. Figure 1-4 illustrates common transmitter assemblies with the bolt length required for proper transmitter assembly.
  • Page 6 Table 1-1 . If bolt material is not shown in Table 1-1, contact the local Emerson representative for more information. Use the following bolt installation procedure: Procedure 1. Carbon steel bolts do not require lubrication and the stainless steel bolts are coated with a lubricant to ease installation.
  • Page 7 October 2018 Quick Start Guide 5. Verify the flange bolts are protruding through the sensor module before applying pressure (see Figure 1-5). Example Table 1-1: Torque Values for the Flange and Flange Adapter Bolts Bolt material Head markings Initial torque Final torque Carbon Steel 300 in-lb...
  • Page 8 Quick Start Guide October 2018 O-rings with flange adapters WARNING Failure to install proper flange adapter O-rings may cause process leaks, which can result in death or serious injury. Only use the O-ring that is designed for its specific flange adapter. A.
  • Page 9: Consider Housing Rotation

    October 2018 Quick Start Guide Consider housing rotation About this task To improve field access to wiring or to better view the optional LCD display: Procedure 1. Loosen the housing rotation set screw. 2. Turn the housing up to 180° left or right of its original (as shipped) position.
  • Page 10: Set The Switches

    Quick Start Guide October 2018 Set the switches The transmitter’s default configuration sets the alarm condition to high (HI) and the security to off. Procedure 1. If the transmitter is installed, secure the bus and remove power. 2. Required: Remove the transmitter cover opposite the field terminal side.
  • Page 11: Connect Wiring And Power Up

    October 2018 Quick Start Guide Connect wiring and power up About this task CAUTION Do not connect the power across the test terminals. Power could damage the test diode in the test connection. Twisted pairs yield best results. Use 24 to 14 AWG wire and do not exceed 5,000 ft.
  • Page 12 Quick Start Guide October 2018 Figure 4-1: Transmitter Wiring Without optional process temperature With optional process temperature connection connection RL ≥ 250Ω RL ≥ 250Ω A. Power supply Note Installation of the transient protection terminal block does not provide transient protection unless the Rosemount 3051SMV housing is properly grounded.
  • Page 13 October 2018 Quick Start Guide Figure 4-2: Load Limitation Maximum loop resistance = 43.5 x (power supply voltage – 12.0) 1322 1000 Operating region 12.0 42.4 Voltage (Vdc) HART communication requires a minimum loop resistance of 250Ω Install optional process temperature input (Pt 100 RTD sensor) About this task Note...
  • Page 14 Quick Start Guide October 2018 Figure 4-3: Rosemount 3051SMV RTD Wiring Connection A. Ground lug B. RTD cable assembly wires C. Pt 100 RTD sensor Rosemount 3051SMV...
  • Page 15: Engineering Assistant Installation

    The Rosemount 3051SMV Engineering Assistant software is required to complete the flow configuration. NOTICE To ensure correct operation, download the most current version of the Engineering Assistant software at Emerson.com/Rosemount-Engineering- Assistant. System requirements The following are the minimum system requirements to install the ™...
  • Page 16 Quick Start Guide October 2018 Note Engineering Assistant versions 6.1 or later require the use of ® Microsoft .NET Framework version 4.0 or later. If .NET version 4.0 is not currently installed, the software will be automatically installed during the Engineering Assistant installation. Microsoft .NET version 4.0 requires an additional 200 MB of disk space.
  • Page 17: Flow Configuration

    October 2018 Quick Start Guide Flow configuration ™ Rosemount 3051SMV Engineering Assistant 6.1 or later The Rosemount 3051SMV Engineering Assistant is designed to guide the user through the setup of the flow configuration for a Rosemount 3051SMV. The flow configuration screens allow the user to specify the fluid, operating conditions, and information about the primary element, including inside pipe diameter.
  • Page 18 Quick Start Guide October 2018 Basic navigation overview Figure 6-1: Engineering Assistant Basic Navigation Overview Screen Description of use compo nent The navigation tabs contain the flow configuration information. In Offline mode, each tab will not become active until the required fields on the previous tab are completed.
  • Page 19 October 2018 Quick Start Guide Screen Description of use compo nent Any configuration information that needs to be entered or reviewed will appear in this portion of the screen. These menus navigate to the Configure Flow, Basic Setup, Device, Variables, Calibration, and Save/Send Configuration tabs. These buttons navigate to Config/Setup, Device Diagnostics or Process Variables sections.
  • Page 20 Quick Start Guide October 2018 Use Preferences tab About this task The Preferences tab, shown in Figure 6-3, allows you to select the preferred engineering units to display. Procedure 1. Select the preferred engineering units. 2. If Custom Units are selected, configure the Individual Parameters. 3.
  • Page 21 October 2018 Quick Start Guide Figure 6-4: Fluid Selection Tab Note The following example will show a flow configuration for the database gas air used with a Rosemount 405C Conditioning Orifice Plate as the primary element. The procedure to set up any other fluid with any other primary element will be similar to this example.
  • Page 22 Quick Start Guide October 2018 8. Select Next to proceed to the Fluid Properties tab. Fluid properties Note The Fluid Properties tab is an optional step and is not required to complete a flow configuration. The Fluid Properties tab for the database gas air is shown in Figure 6-5.
  • Page 23 October 2018 Quick Start Guide Figure 6-6: Primary Element Selection Tab Continuing with the example configuration: Procedure 1. Expand the Conditioning Orifice Plate category. 2. Select 405C/3051SFC. 3. Enter the measured Meter Tube Diameter (pipe ID) at a reference temperature. If the meter tube diameter cannot be measured, select a Nominal Pipe Size and Pipe Schedule to input an estimated value for the meter tube diameter (English units only).
  • Page 24 Quick Start Guide October 2018 Save/send configuration About this task The Save/Send Configuration tab shown in Figure 6-7 allows you to verify, save, and send the configuration information to the transmitter with the fully compensated mass and energy flow feature board. Procedure 1.
  • Page 25 October 2018 Quick Start Guide 4. The Engineering Assistant Device Connection screen will appear, see Figure 6-8. Figure 6-8: Engineering Assistant Device Connection Screen 5. Select the Search button located in the lower right hand corner of the screen. Engineering Assistant will begin to search for connected devices.
  • Page 26: Verifying Device Configuration

    Quick Start Guide October 2018 Verifying device configuration ™ ® Use Rosemount 3051SMV Engineering Assistant or any HART -compliant master to communicate with and verify configuration of the Rosemount 3051SMV. Table 7-1 shows the Field Communicator fast keys for the fully compensated mass and energy flow.
  • Page 27 October 2018 Quick Start Guide Table 7-1: Fast Keys for Fully Compensated Mass and Energy Flow (continued) Function Fast Key sequence Energy Rate Units 1, 3, 3, 2 Energy Reading and Status 1, 4, 2, 1, 2 Equipped Sensors 1, 4, 4, 4 Field Device Information 1, 4, 4, 1 Flow Calculation Type...
  • Page 28 Quick Start Guide October 2018 Table 7-1: Fast Keys for Fully Compensated Mass and Energy Flow (continued) Function Fast Key sequence Totalizer Configuration 1, 4, 1, 3 Totalizer Reading and Status 1, 4, 2, 1, 3 Totalizer Units 1, 3, 3, 3 Variable Mapping 1, 4, 3, 4 Write Protect...
  • Page 29 October 2018 Quick Start Guide Table 7-2: Fast Keys for Direct Process Variable Output (continued) Function Fast Key sequence LCD Configuration 1, 3, 8 Loop Test 1, 2, 2 Module Temperature Reading and Status 1, 4, 2, 1, 5 Module Temperature Units 1, 3, 3, 5 Poll Address 1, 4, 3, 3, 1...
  • Page 30: Trimming The Transmitter

    Quick Start Guide October 2018 Trimming the transmitter Transmitters are shipped fully calibrated per request or by the factory default of full scale. Zero trim A zero trim is a single-point adjustment used for compensating mounting position and line pressure effects on static and differential pressure sensors. When performing a zero trim, ensure that the equalizing valve is open and all wet legs are filled to the correct level.
  • Page 31: Safety Instrumented Systems Installation

    October 2018 Quick Start Guide Safety instrumented systems installation For safety certified installations, refer to the appropriate reference manual for the installation procedure and system requirements: • For DP only measurements (measurement type D) refer to the Rosemount 3051S Reference Manual.
  • Page 32: Product Certifications

    A copy of the EU Declaration of Conformity can be found at the end of the Quick Start Guide. The most recent revision of the EU Declaration of Conformity can be found at Emerson.com/Rosemount. Ordinary Location Certification As standard, the transmitter has been examined and tested to determine that...
  • Page 33 October 2018 Quick Start Guide Note Transmitters marked with NI CL 1, DIV 2 can be installed in Division 2 locations using general Division 2 wiring methods or Nonincendive Field Wiring (NIFW). See Drawing 03151-1206. IE US FISCO Intrinsically Safe Certificate FM16US0233 Standards FM Class 3600 –...
  • Page 34 Quick Start Guide October 2018 Standards CAN/CSA C22.2 No. 0-10, CSA Std C22.2 No. 25-1966, CSA Std C22.2 No. 30-M1986, CSA C22.2 No. 94.2-07, CSA Std C22.2 No. 213-M1987, CAN/CSA C22.2 60079-11:14, CAN/CSA-C22.2 No. 61010-1-12, ANSI/ISA 12.27.01-2003, CSA Std C22.2 No. 60529:05 (R2010) Markings FISCO Intrinsically Safe Class I, Division 1;...
  • Page 35 October 2018 Quick Start Guide I1 ATEX Intrinsic Safety Certificate Baseefa08ATEX0064X Standards EN 60079-0:2012, EN 60079-11:2012 Markings II 1 G Ex ia IIC T4 Ga, T4(–60 °C ≤T ≤ +70 °C) ® ™ Parameter HART SuperModule RTD (for 3051SFx) OUNDATION Fieldbus only HART...
  • Page 36 Quick Start Guide October 2018 ND ATEX Dust Certificate BAS01ATEX1374X Standards EN 60079-0:2012, EN 60079-31:2009 Markings II 1 D Ex ta IIIC T105 °C T 95 °C Da, (–20 °C ≤T ≤ +85 °C), = 42.4 V Special Conditions for Safe Use (X): 1.
  • Page 37 October 2018 Quick Start Guide Special Conditions for Safe Use (X): 1. This device contains a thin wall diaphragm less than 1 mm thickness that forms a boundary between EPL Ga (process connection) and EPL Gb (all other parts of the equipment). The model code and datasheet are to be consulted for details of the diaphragm material.
  • Page 38 Quick Start Guide October 2018 Parameter HART SuperModule RTD (for 3051SFx) OUNDATION Fieldbus only HART Fieldbus Current I 300 mA 300 mA 300 mA 2.31 mA 18.24 mA Power P 1.3 W 887 mW 17.32 137 mW Capacitance 14.8 nF 0.11 µF 0.8 nF Inductance L...
  • Page 39 October 2018 Quick Start Guide 6.5.1 of IEC 60079-15:2010. This must be taken into account during installation. 10.1.5 Brazil E2 INMETRO Flameproof Certificate UL-BR 15.0393X Standards ABNT NBR IEC 60079-0:2008 + Corrigendum 1:2011, ABNT NBR IEC 60079-1:2009 + Corrigendum 1:2011, ABNT NBR IEC 60079-26:2008 + Corrigendum 1: 2008 Markings Ex db IIC T* Ga/Gb, T6(–60 °C≤...
  • Page 40 Quick Start Guide October 2018 Parameter HART Fieldbus Input Input Voltage U 30 V 30 V 30 V 30 V Current I 300 mA 2.31 mA 300 mA 18.24 mA Power P 17.32 mW 1.3 W 137 mW Capacitance C 14.8 nF 0.8 nF Inductance L...
  • Page 41 October 2018 Quick Start Guide Table 10-1: Input Parameters (continued) 3051S …A…M7, M8, or 30 V 300 mA 1.0 W 12 nF 60 µH M9; 3051SF …A…M7, M8, or M9; 3051SAL…C… M7, M8, or M9 3051SAL or 3051SAM 30 V 300 mA 1.0 W 12 nF...
  • Page 42 Quick Start Guide October 2018 T code Ambient temperature range T4/T5 –60 °C +80 °C (–76 °F +176 °F) 3. The earth connection facility in the enclosure should be connected reliably. 4. During installation, use and maintenance of the product in explosive atmosphere, observe the warning “Do not open cover when circuit is alive”.
  • Page 43 October 2018 Quick Start Guide Standards 3051SMV: GB3836.1-2010, GB3836.4-2010, GB3836.20-2010 3051SFx: GB3836.1/4-2010, GB3836.20-2010, GB12476.1-2000 Markings 3051SMV: Ex ia IIC T4 Ga 3051SFx: Ex ia IIC T4 Ga, Ex tD A20 T 105 °C T 95 °C; IP66 Special Conditions for Safe Use (X): 1.
  • Page 44 Quick Start Guide October 2018 9. During installation, use, and maintenance in explosive dust atmosphere, observe the warning “Do not open when an explosive dust atmosphere is present”. 10. Maintenance should be done when no explosive dust atmosphere is present. 11.
  • Page 45 October 2018 Quick Start Guide Table 10-2: Temperatur Ambient temperature Process temperature e class –40 °C to +70 °C (–40 °F to +158 –60 °C to +70 °C (–76 °F to +158 °F) °F) –40 °C to +75 °C (–40 °F to +167 –60 °C to +80 °C (–76 °F to +176 °F) °F)
  • Page 46 Quick Start Guide October 2018 Combination of E5 and I5 Combination of E6 and I6 Combination of E7, I7, and N7 Combination of E1, I1, E6, and I6 Combination of E5, I5, E6, and I6 Combination of E1, I1, E5, and I5 Combination of E1, I1, E5, I5, E6, and I6 Combination of EM and IM Combination of EP and IP...
  • Page 47 October 2018 Quick Start Guide Enclosure D/IP66/IP68 SLL Lloyds Register (LR) Type Approval Certificate 11/60002 Application Environmental categories ENV1, ENV2, ENV3, and ENV5. [HART only] Quick Start Guide...
  • Page 48 Quick Start Guide October 2018 10.2 Declaration of Conformity Rosemount 3051SMV...
  • Page 49 October 2018 Quick Start Guide Quick Start Guide...
  • Page 50 Quick Start Guide October 2018 Rosemount 3051SMV...
  • Page 51 October 2018 Quick Start Guide 10.3 ChinaRoHS Rosemount 3051SMV China RoHS List of Rosemount 3051SMV Parts with China RoHS Concentration above MCVs / Hazardous Substances Hexavalent Polybrominated Polybrominated Part Name Lead Mercury Cadmium Chromium biphenyls diphenyl ethers (Pb) (Hg) (Cd) (Cr +6) (PBB) (PBDE)
  • Page 52 The Emerson logo is a Facebook.com/Rosemount trademark and service mark of Emerson Electric Youtube.com/user/ Co. Rosemount is mark of one of the Emerson RosemountMeasurement family of companies. All other marks are the Google.com/+RosemountMeasurement property of their respective owners.