Installation Procedures - Emerson Rosemount 4600 Reference Manual

Oil & gas panel transmitter
Hide thumbs Also See for Rosemount 4600:
Table of Contents

Advertisement

Installation
September 2016
3.5

Installation procedures

For dimensional drawing information refer to
on
page
3.5.1
Zero and span target orientation
Mount the transmitter with sufficient clearance so the zero and span targets are accessible.
3.5.2
Mount the transmitter
Panel mount
Electrical connection
1.
2.
3.
Process connection
1.
2.
Note
Apply torque only to the hex flat located at the process end of the transmitter. Do not apply
torque to the transmitter body or electrical connection - severe damage could result. Do
not exceed 100 ft-lbs.
Note
Integral conduit seal meets the requirements of NEC
No additional conduit seal is required.
Note
The Rosemount
design which meets the requirements of NEC 2002 section 501:5 (F)(3) and API 14F 6.8.2.2.
No additional process sealing is required.
Impulse piping
The piping between the process and the transmitter must accurately transfer the pressure
to obtain accurate measurements. There are five possible sources of error: pressure
transfer, leaks, friction loss (particularly if purging is used), trapped gas in a liquid line and
liquid in a gas line.
See
"Safety messages" on page 25
28
www.aotewell.com
51.
Pull the leads through the threaded mounting hole in the panel wall.
Hand tighten the electrical connection into the mounting hole.
Using a wrench on the hex flat at the process connection, apply sufficient torque to
prevent transmitter vibration. Do not exceed 100 ft-lbs.
Hand tighten the appropriate sized impulse piping into the process connection.
Using a wrench on the hex flat at the impulse piping connection, apply enough
torque to prevent the process fluid from leaking. Do not exceed 100 ft-lbs.
4600 Oil & Gas Pressure Transmitter features a reliable dual process seal
for complete warning information.
sales@aotewell.com
Reference Manual
00809-0100-4022, Rev GA
Appendix A: Specification and Reference Data
®
2002 section 501:5 (A) and 501.5 (B).
Industry Automation
Installation
+86-755-8660-6182

Advertisement

Table of Contents
loading

Table of Contents