TIP CALIBRATION

Tip offset values are the distance between the model and support tips in the X, Y and Z directions. Accurate tip
offset values ensure that support toolpaths are accurately located in reference to model toolpaths. Inaccurate tip
offset values can cause part quality issues, such as support material embedded in a part or improperly
supported parts.
The automatic tip calibration registers the support tip relative to the model tip. Auto-calibration is triggered any
time the ribbon cables are disconnected from the printer heads while the printer is powered ON. The calibration
will occur immediately prior to building the next part. You cannot build parts on the printer until the printer's tips
are calibrated.
Automatic tip calibration can also be initiated from the touchscreen using the following procedure.
Performing Automatic Tip Calibration
1.
Place a new substrate onto the platen and lock the substrate into its build position by lifting up on
the substrate ejection handle.
2.
From the touchscreen, navigate to Tools > Calibration. The printer's calibration status will be
displayed within the Tip Calibration row. Calibrated or Not Calibrated will be displayed depending
on the printer's current calibration status.
3.
Press anywhere within the Tip Calibration row to display the Tip Calibration page.
4.
The Tip Calibration page contains an option for performing an Automatic Tip Calibration as well
as a Manual Tip Calibration. Press the designated Start button to initiate the Automatic Tip
Calibration.