AVAILABLE MATERIALS

The F123 Series can use a variety of model materials, in a range of colors. QSR Soluble Release support
material is used in conjunction with all model materials, except for PLA. When building with PLA material, PLA is
used for both model and support materials.
Printer Model
F170
F270
F370

MINIMUM CLEARANCES

Side Clearance
Rear Clearance
Front Clearance
Overhead Clearance

OPERATING ENVIRONMENT

SAFE ENVIRONMENT

Connect equipment to a grounded facility power source. Do not defeat or bypass the ground
lead.
Know the location of equipment branch circuit interrupters or circuit breakers and how to turn
them on and off in case of emergency.
Know the location of fire extinguishers and how to use them. Use only ABC type extinguishers
on electrical fires.
Know local procedures for first aid and emergency assistance at the customer facility.
Use adequate lighting at the equipment.
Maintain the recommended range of temperature and humidity in equipment area.
Do not use this product in an environment containing volatile or flammable compounds.

ENVIRONMENTAL REQUIREMENTS

The F123 Series printer is for indoor use only.
Air quality conditions with excessive solid particulates (conductive or non-conductive) may
result in system damage.
Air quality conditions in which airborne oils are allowed to accumulate on or within the printer
can damage the plastic components.
System operating temperature shall be in the range of 59°F to 86°F (15°C to 30°C), with
relative humidity range of 30% to 70% non-condensing.
System storage temperature shall be in the range of 32°F to 95°F (0°C to 35°C), with relative
humidity range of 20% to 90% non-condensing.
Altitude shall not exceed 6561.68 feet (2000 m).
Material storage shall be in the range of 55°F to 86°F (13°C to 30°C), with relative humidity less
than 70%.
Noise emission (acoustic):
<32dBA when idle
<46dBA when building
Available Materials
ABS, ASA, PLA
ABS, ASA, PLA
ABS, ASA, PLA, PC-ABS
Minimum 4 inches (10.16 cm) on each side
Minimum 6 inches (15.24 cm)
Minimum 20 inches (50.80 cm)
Minimum 20 inches (50.80 cm)