Changing Heads; Replacing A Standard Head - Stratasys F170 Operation And Maintenance Manual

F123 series shared office 3d printers
Hide thumbs Also See for F170:
Table of Contents

Advertisement

CHANGING HEADS

When a head reaches 1500 build hours (odometer limit), a warning will be displayed on the User Interface and
the head's Head Status Icon will be highlighted in red on the Materials page. You can continue using a head
which has exceeded its odometer limit, but it is highly recommended that you change the head as part quality
will be unpredictable.

REPLACING A STANDARD HEAD

The information within this section is meant to guide you through the process of changing a standard head.
Although the instructions below depict the replacement of the model head, the same procedure applies to both
the model and support head. The process for replacing a PLA head varies slightly from the process for replacing
a standard head.
1.
Unload material from the head that will be replaced.
2.
With the printer powered ON, open the top cover.
Note: Replacing a head while the printer is powered ON will ensure that an
Automatic Tip Calibration is performed after the replacement process is compete.
Power is automatically removed from the head and all motors when the top cover
is opened.
3.
Depress the release tab and unclip the head ribbon cable for the head that will be replaced
(model head is on the left, support head is on the right).
4.
Disconnect the material tube for the head that will be replaced.
5.
Unlock the head release lever for the head that will be replaced.
Material
Tube
Head Release
Lever
Head Ribbon Cable
67

Advertisement

Table of Contents
loading

This manual is also suitable for:

F270F370