Digi Connect Sensor User Manual page 117

Hide thumbs Also See for Connect Sensor:
Table of Contents

Advertisement

CLI
Option
command
Description
Enables or disables the device to monitor a
Rising and
wem
digital input during sleep mode as follows
falling edge
(they are either all On or all Off when using
wake
the CLI for configuration):
Enable pullup
puen
Enables or disables the internal pull-up
resistor to drive a logic level voltage. For
example, use this to drive a logic voltage
across a mechanical switch to read the
value (open or closed) of the mechanical
switch.
Sensor
dsc
Specifies description of the sensor for this
description
input source.
Rising edge wake alarm: When
n
enabled, wakes the device when the
digital input changes from low
voltage to high voltage (rising edge)
and reports the value to Remote
Manager with the other sensor and
device data.
Falling edge wake alarm: When
n
enabled, wakes the device when the
digital input changes from high
voltage to low voltage (falling edge)
and reports the value to Remote
Manager with the other sensor and
device data.
Value options
rise
n
fall
n
Enable both alarms using a comma
n
separated command without spaces
(such as set din1 wem=rise,fall)
on
n
off
n
Text
Default
Empty (all edge wake
alarms off)
off