Configuring Vlt On The Fn Iom - Dell PowerEdge FX2 Deployment Manual

Configuring, testing and validating vlt on a pair of fn410s i/o modules in a poweredge fx2 chassis (v2.2)
Hide thumbs Also See for PowerEdge FX2:
Table of Contents

Advertisement

Note: When an FN IOM is connected to a Cisco Nexus in the default state, a number of DCBX (Data
Center Bridging Exchange) error messages are logged and shown on the FN IOM serial console
each time a port or port channel is shutdown or brought up. To suppress these messages, either
configure DCBX on the FN IOM and Nexus switches (which is out of the scope of this document) or
disable DCB on the FN IOM with the command: Dell(conf)#no dcb enable
9.1.2

Configuring VLT on the FN IOM

In this section, the VLT domain and VLTi (VLT interconnect) participating links are configured (Figure
47).
FC630 Server
PowerEdge FX2 – FN I/O Module – VLT Deployment Guide | Version 2.2
72
VLT Domain
FN410S-A1
Te 0/9
VLTi (Po 127)
Te 0/9 Te 0/10
FN410S-A2
FN410S VLT Configuration and VLTi setup
Te 0/10
vPC Domain