Configuring The Fn Iom For Programmable Mux Mode - Dell PowerEdge FX2 Deployment Manual

Configuring, testing and validating vlt on a pair of fn410s i/o modules in a poweredge fx2 chassis (v2.2)
Hide thumbs Also See for PowerEdge FX2:
Table of Contents

Advertisement

8.1.1

Configuring the FN IOM for programmable MUX mode

In this section, the switch is set to Programmable MUX (PMUX) mode.
In Figure 38, configuration mode is used to set the switch to PMUX IOM mode, then the configuration
is saved and the switch is reloaded. Once the reload is complete, the IOM mode is verified using the
show system stack-unit iom- mode command. Then, the management IP address is assigned
to allow VLT heartbeats as well as SSH/telnet access.
Note: Only the VLT-related portions of the configurations are shown.
PowerEdge FX2 – FN I/O Module – VLT Deployment Guide | Version 2.2
53
FN410S-A1
Configure the IOM for
Programmable MUX mode
configure
stack-unit 0 iom-mode
programmable-mux
end
Verify that the system is set to move
to Programmable-MUX mode for the
next-boot and reload
show system stack-unit 0
iom-mode
reload
Confirm the iom-mode
Configure the Management IP
address
show system stack-unit 0
iom-mode
configure
interface ma0/0
ip address
172.25.189.27/16
Configuring the FN IOM for PMUX mode
FN410S-A2
Configure the IOM for
Programmable MUX mode
configure
stack-unit 0 iom-mode
programmable-mux
end
Verify that the system is set
to move to Programmable-
MUX mode for the next-boot
and reload
show system stack-unit
0 iom-mode
reload
Confirm the iom-mode
Configure the Management
IP address
show system stack-unit
0 iom-mode
configure
interface ma0/0
ip address
172.25.189.28/16