9.4

Environment Four: Verify VPC connectivity

Use the following commands (Table 15) to verify that the vPC configuration is valid.
Command
show feature
show vpc brief
show interface port-channel
show running-config vpc
show vpc peer-keepalive
The output of the show feature command shown below has been passed to grep and filtered for
any enabled features. The results show that lacp and vpc are both enabled.
Show vpc brief gives a quick verification that the vPC domain is functioning. The important point to
note in the output of this command are Configuration, Per-vlan and Type-2 consistency
all show the status of success.
PowerEdge FX2 – FN I/O Module – VLT Deployment Guide | Version 2.2
84
vPC show commands used to verify the vPC configuration
Nx5672-1
Nx5672-1# show feature | grep enabled
lacp
lldp
sshServer
telnetServer
vpc
Purpose
Reports if vPC is enabled or not
Displays brief information about the vPCs
Displays vPC status and vPC number of the port
channel
Displays running configuration for vPCs
Displays information about the peer-keepalive
1
enabled
1
enabled
1
enabled
1
enabled
1
enabled