Dell PowerEdge FX2 Deployment Manual page 80

Configuring, testing and validating vlt on a pair of fn410s i/o modules in a poweredge fx2 chassis (v2.2)
Hide thumbs Also See for PowerEdge FX2:
Table of Contents

Advertisement

In these next steps, the port channel and port channel members for the vPC peer link are configured.
Interface ports Ethernet 1/19 and 1/20 are added to port channel 55 and set to use LACP
unconditionally using the mode active option.
Configure the port channel and port
channel members for the vPC peer
link
Create the port channel
Enable the switchport mode trunk
and assign as vpc peer link
interface port-channel 55
description "vPC Peer-Link
to Nx5672-2"
switchport mode trunk
switchport mode trunk
allowed vlan all
no shutdown
vpc peer-link
exit
Assign interfaces to the port
channel and enable LACP
interface ethernet 1/19-20
description "Link to
Nx5672-2"
switchport mode trunk
channel-group 55 mode
active
no shutdown
exit
PowerEdge FX2 – FN I/O Module – VLT Deployment Guide | Version 2.2
80
Nx5672-1
vPC peer link setup
Nx5672-2
Configure the port channel and port
channel members for the vPC peer
link
Create the port channel
Enable the switchport mode trunk
and assign as vpc peer link
interface port-channel 55
description "vPC Peer-Link
to Nx5672-1"
switchport mode trunk
switchport mode trunk
allowed vlan all
no shutdown
vpc peer-link
exit
Assign interfaces to the port
channel and enable LACP.
interface ethernet 1/19-20
description "Link to
Nx5672-1"
switchport mode trunk
channel-group 55 mode
active
no shutdown
exit