Dell PowerEdge FX2 Deployment Manual page 82

Configuring, testing and validating vlt on a pair of fn410s i/o modules in a poweredge fx2 chassis (v2.2)
Hide thumbs Also See for PowerEdge FX2:
Table of Contents

Advertisement

Configure the port channel and port
channel member links for
downstream connectivity to the FN
IOMs
interface port-channel 100
description "vPC to FN410S"
switchport mode trunk
switchport mode trunk
allowed vlan all
vpc 100
no shutdown
exit
Assign interfaces to the port
channel and enable LACP
interface ethernet 1/1-2
description "Link to
FN410S"
switchport mode trunk
channel-group 100 mode
active
no shutdown
exit
PowerEdge FX2 – FN I/O Module – VLT Deployment Guide | Version 2.2
82
Nx5672-1
Port channel configuration to IOM from vPC
Nx5672-2
Configure the port channel and port
channel member links for
downstream connectivity to the FN
IOMs
interface port-channel 100
description "vPC to FN410S"
switchport mode trunk
switchport mode trunk
allowed vlan all
vpc 100
no shutdown
exit
Assign interfaces to the port
channel and enable LACP
interface ethernet 1/1-2
description "Link to
FN410S"
switchport mode trunk
channel-group 100 mode
active
no shutdown
exit

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poweredge fn410s

Table of Contents