PowerEdge FX2 – FN I/O Module – VLT Deployment Guide | Version 2.2
38
FN410S- A1
Configure the peer LAG, and then
configure upstream links for the
mVLT connection
Create the port channel.
interface port-channel 101
description "PO to CNA NIC
1"
portmode hybrid
switchport
vlt-peer-lag po101
no shutdown
exit
Configure the internal port and set
the port channel.
interface te0/1
no switchport
port-channel-protocol lacp
port-channel 101 mode
active
exit
no shutdown
Configure the port channel for
upstream links.
interface port-channel 121
description "PO to Dell
S4810"
portmode hybrid
switchport
vlt-peer-lag po121
no shutdown
exit
Configure the interfaces that will
participate in the VLT port channel.
FN410S- A2
Configure the peer LAG, and
then configure upstream links
for the mVLT connection.
Create the port channel.
interface port-channel
101
description "PO to
CNA NIC 1"
portmode hybrid
switchport
vlt-peer-lag po101
no shutdown
exit
Configure the internal port
and set the port channel.
interface te0/1
no switchport
port-channel-protocol
lacp
port-channel 101
mode active
exit
no shutdown
Configure the port channel for
upstream links.
interface port-channel
121
description "PO to
Dell S4810"
portmode hybrid
switchport
vlt-peer-lag po121
no shutdown
exit
Configure the interfaces that
will participate in the VLT port
channel.

Advertisement