Environment Two: Configuring The Dell Networking S4810 - Dell PowerEdge FX2 Deployment Manual

Configuring, testing and validating vlt on a pair of fn410s i/o modules in a poweredge fx2 chassis (v2.2)
Hide thumbs Also See for PowerEdge FX2:
Table of Contents

Advertisement

Connection to server NICs and connections to S4810 switches
7.2

Environment Two: Configuring the Dell Networking S4810

In this section, the S4810 switches are configured (Figure 35). The configuration steps outlined below
are repeated on both IOMs. When validating the configurations in this guide the following management
IP addresses (Table 7) were used.
The VLT active/active capabilities of the S4810 and the IOM are the same. Therefore, the
configurations should look and behave in the same manner.
PowerEdge FX2 – FN I/O Module – VLT Deployment Guide | Version 2.2
39
interface range te0/11-12
description "Link to Dell
S4810"
no switchport
port-channel-protocol lacp
port-channel 121 mode
active
exit
no shutdown
exit
Management IP Addresses
Hostname
S4810-1
S4810-2
IP Address
172.25.190.37
172.25.190.38
interface range
te0/11-12
description "Link to
Dell S4810"
no switchport
port-channel-protocol
lacp
port-channel 121
mode active
exit
no shutdown
exit
Subnet
255.255.0.0
255.255.0.0

Advertisement