7.1.1

Configuring the IOM for Full Switch mode

In this section, the switch is set to Full Switch mode.
In Figure 30, Global Configuration mode is used to set the switch to Full Switch mode. Then the
configuration is saved and the switch is reloaded. Once the reload is complete, the IOM mode is
verified using the show system stack-unit 0 iom-mode command. Then, the management IP
address is assigned to allow VLT heartbeats as well as SSH/telnet access.
Note: Only the VLT-related portions of the configurations are shown.
Configuring the IOM for Full Switch mode
PowerEdge FX2 – FN I/O Module – VLT Deployment Guide | Version 2.2
34
FN410S-A1
Configure the IOM for Full Switch
mode
configure
stack-unit 0 iom-mode full-
switch
end
Verify that the system is set to move
to Full Switch mode for the next-
boot, save, and reload
show system stack-unit 0
iom-mode
copy running-config
startup-config
reload
Confirm the iom-mode
Configure the Management IP
address
show system stack-unit 0
iom-mode
configure
interface ma0/0
ip address
172.25.189.27/16
no shut
FN410S-A2
Configure the IOM for Full
Switch mode
configure
stack-unit 0 iom-mode
full-switch
end
Verify that the system is set
to move to Full Switch mode
for the next-boot, save, and
reload
show system stack-unit
0 iom-mode
copy running-config
startup-config
reload
Confirm the iom-mode
Configure the Management
IP address
show system stack-unit
0 iom-mode
configure
interface ma0/0
ip address
172.25.189.28/16
no shut