Port Channel 200 is created and connectivity to the external network is configured.
Configure the port channel and port
channel members for upstream
connectivity to the external network
interface port-channel 200
description "vPC to
External Network"
switchport mode trunk
switchport mode trunk
allowed vlan all
vpc 200
no shutdown
exit
Assign an interface to the port
channel and enable LACP
interface ethernet 1/24
description "Link to
External Network"
switchport mode trunk
channel-group 200 mode
active
no shutdown
exit
9.3

Environment Four: Verify VLT connectivity

VLT connectivity can be checked using the VLT commands listed in Table 14.
Command
show vlt brief
show vlt detail
show mac-address-table
See section
commands.
PowerEdge FX2 – FN I/O Module – VLT Deployment Guide | Version 2.2
83
Nx5672-1
Port channel configuration to external network from vPC
show commands
Purpose
Displays brief information about the VLT configuration
Displays running configuration for VLT members
Displays the MAC address table
8.3 Environment Three: Verifying VLT Connectivity
Nx5672-2
Configure the port channel and port
channel members for upstream
connectivity to the external network
interface port-channel 200
description "vPC to
External Network"
switchport mode trunk
switchport mode trunk
allowed vlan all
vpc 200
no shutdown
exit
Assign an interface to the port
channel and enable LACP
interface ethernet 1/24
description "Link to
External Network"
switchport mode trunk
channel-group 200 mode
active
no shutdown
exit