Table 4-1
Error Messages (continued)
Error/Warning
ID
Error/Warning Message
EID-2030
An error occurred during provisioning.
EID-2031
An error occurred while adding the node.
EID-2032
The circuit could not be renamed.
{0}
EID-2033
An error occurred during validation.
{0}
EID-2034
Network circuits could not be added:
{0}
EID-2035
The source and destination nodes are not connected.
EID-2036
The {0} cannot be deleted.
LAN Access has been disabled on this node and this {0} is
needed to access the node.
EID-2037
The attribute for {0} cannot be found.
EID-2038
The protection operation is invalid.
EID-2040
Please select a node first.
EID-2041
No paths are available on this link. Please make another
selection.
EID-2042
This span is not selectable. Only the green spans with an arrow
may be selected.
EID-2043
This node is not selectable. Only the source node and nodes
attached to included spans (blue) are selectable. Selecting a
selectable node will enable its available outgoing spans.
EID-2044
This link may not be included in the required list. Constraints
only apply to the primary path. Each node may have a
maximum of one incoming signal and one outgoing link.
EID-2045
This link may not be included in the required list. Only one
outgoing link may be included for each node.
EID-2047
Please enter a valid value for the slot number.
EID-2048
Please enter a valid value for the port number.
EID-2050
The new circuit could not be destroyed.
EID-2051
The circuit cannot be downgraded.
{0}
Cisco ONS 15310-MA SDH Troubleshooting Guide, Release 9.1 and Release 9.2
4-6
Chapter 4
Description
There was an error during provisioning.
There was an error while adding a node.
CTC could not rename the circuit.
There was an internal error while validating
the user changes after the Apply button was
pressed. This error can occur in the Edit
Circuit dialog box or in the MS-SPRing
table in the shelf view (rare condition).
Refer to the error message text.
Refer to the error message text.
You cannot delete the DCC/GCC link as it
is needed to access the node.
CTC cannot find an attribute for the
specified item.
The protection operation you tried to
execute is invalid.
You must select a node before performing
the task.
You must select a link that has paths
available.
Refer to the error message text.
Refer to the error message text.
You must select only one link going in and
out of a node. Selecting more than one link
is contradictory to the path selection
algorithm.
Refer to the error message text.
There was an error due to an invalid slot
number.
There was an error due to an invalid port
number.
CTC could not destroy the new circuit.
The specified circuit cannot be
downgraded.
Error Messages