Download Print this page

Cisco ONS 15454 Troubleshooting Manual page 23

Hide thumbs Also See for ONS 15454:

Advertisement

Chapter 4
Error Messages
Table 4-1
Error Messages (continued)
Error/Warning
ID
Error/Warning Message
EID-3158
Probable causes:
- Unable to switch, because a similar or higher priority
condition exists on a peer or far-end card.
- A loopback is present on the working port.
1
EID-3159
An error occurred while applying the operation.
EID-3160
An error occurred while provisioning the {0}.
EID-3161
An error occurred while upgrading the ring.
EID-3162
This protection operation cannot be set because the protection
operation on the other side has been changed but not yet
applied.
EID-3163
The data in row {0} cannot be validated.
EID-3164
The new node ID ({0}) for ring ID {1} duplicates the ID of
node {2}.
EID-3165
The ring ID provided is already in use. Ring IDs must be
unique.
EID-3166
An error occurred while refreshing the {0} table.
EID-3167
The slot is already in use.
EID-3168
An error occurred while provisioning.
EID-3169
An error occurred while adding the card.
EID-3170
You cannot delete this card: {0}.
EID-3171
An error occurred while creating the trap destination.
EID-3172
No RMON thresholds were selected.
EID-3173
The contact ''{0}'' cannot exceed {1} characters.
EID-3174
The description ''{0}'' cannot exceed {1} characters.
EID-3175
The operator identifier ''{0}'' cannot exceed {1} characters.
EID-3176
The operator specific information ''{0}'' cannot exceed {1}
characters.
78-19418-01
Cisco ONS 15310-MA SDH Troubleshooting Guide, Release 9.1 and Release 9.2
Description
Refer to the error message text.
CTC encountered an error while applying
this operation.
CTC encountered the specified error.
An error was encountered while attempting
to upgrade the MS-SPRing. Refer to the
details portion of the error dialog box for
more information.
Refer to the error message text.
CTC cannot validate the data for the
specified row.
The new specified node ID for the specified
ring ID is the same as another node ID.
Refer to the error message text.
CTC encountered an error while refreshing
the specified table.
Refer to the error message text.
An error was encountered while attempting
the specified provisioning operation. Refer
to the details portion of the error dialog box
for more information.
CTC encountered an error while adding the
card.
Refer to the error message text.
CTC encountered an error creating the trap
destination.
Select an RMON threshold.
The specified contact exceeds the specified
character limit.
The specified location exceeds the specified
character limit.
The specified operator identifier exceeds
the specified character limit.
The specified operator specific information
exceeds the specified character limit.
4-23