Chapter 4
Error Messages
Table 4-1
Error Messages (continued)
Error/Warning
ID
Error/Warning Message
EID-5032
An error occurred while accepting the load.
EID-5033
The profile could not be loaded.
An error occurred while decoding the characters.
EID-5034
The profile could not be loaded.
An error occurred while trying to recognize the file format.
EID-5035
The profile could not be loaded.
An error occurred while reading the file.
EID-5036
The GNE hostname {0} is invalid.
EID-5037
Provisionable patchcords cannot be created between
transponder trunk ports and multiplexer/demultiplexer ports on
the same node.
EID-5038
Provisionable patchcords created between transponder trunk
ports and multiplexer/demultiplexer ports must use the same
wavelength:
{0} is not equal to {1}.
EID-5039
Provisionable patchcords created between transponder trunk
ports and multiplexer/demultiplexer ports must use the same
wavelength:
{0} is not equal to {1}.
Please provision the {2} wavelength on {3}.
EID-5040
Provisionable patchcords created between STM1/STM4 ports
and multiplexer/demultiplexer ports are not supported.
EID-5041
Provisionable patchcords created between gray STM-N trunk
ports and multiplexer/demultiplexer ports are not supported.
EID-5042
Provisionable patchcords created between STM-N trunk ports
and multiplexer/demultiplexer ports must use the same
wavelength:
{0} is not equal to {1}.
WID-5043
Warning: Only the line card was provisioned.
The wavelength compatibility check was skipped.
EID-5044
Virtual links can be used only for OCH-Trail circuits.
EID-5045
The virtual link does not have wavelengths available.
WID-5046
Warning: if you select "Use OCHNC Direction," your circuit
will be limited to nodes prior to release 07.00.
EID-5047
Provisionable patchcords created between STM1/STM4 ports
are not supported.
EID-5048
Provisionable patchcords created between gray STM-N trunk
ports are not supported.
78-19418-01
Cisco ONS 15310-MA SDH Troubleshooting Guide, Release 9.1 and Release 9.2
Description
Refer to the error message text.
CTC detected an error while decoding
characters and could not load the profile.
CTC detected an error and could not load
the profile.
CTC could not read the file and is therefore
unable to load the profile.
The specified host name is invalid. CTC
could not resolve the host name to any valid
IP address
You must create provisionable patchcords
between transponder trunk ports and
mux/demux ports that are on different
nodes.
Wavelengths used by provisionable
patchcords for transponder trunk ports and
mux/demux ports must be the same.
Transmitter and receiver port wavelengths
are not equal. Provision the receiver and
transmitter wavelengths on transmitter and
receiver ports respectively.
Refer to the error message text.
Refer to the error message text.
Wavelengths used by provisionable
patchcords for STM-N trunk ports and
mux/demux ports must be the same.
Refer to the warning message text.
Refer to the error message text.
Set wavelengths for the virtual link and
proceed.
Refer to the warning message text.
Refer to the error message text.
Refer to the error message text.