Table 4-1
Error Messages (continued)
Error/Warning
ID
Error/Warning Message
EID-5082
{0} does not support:
- Low-order circuits that have both {1}-protected and
{2}-protected spans and that cross a node that does not have
low-order cross-connect capability.
- High-order circuits that carry low-order circuits with the
parameters described above.
EID-5083
This circuit is not the same size as the existing circuit {0}.
This circuit has size {1} and the existing circuit has size {2}.
EID-5084
The Trunk model could not be found.
{0}
EID-5085
The maximum number of VLAN DB profiles is {0}.
EID-5086
The circuit roll failed.
You cannot bridge and roll the selected circuit because it has a
monitor circuit.
EID-5087
You cannot use same slot for east working and west protect
ports.
EID-5088
You cannot use same slot for east working and west protect
ports.
WID-5089
The maximum number of circuits that can be deleted at a time
is 200.
Do you want to delete the first 200 circuits selected?
EID-5090
This operation cannot be completed.
The selected circuits have different state models;
please select circuits of the same type.
EID-5091
Some PPC terminations were not repaired.
WID-5092
The TL1 encoding mode for the tunnel is being changed.
Do you want to modify the encoding?
EID-5094
Currently, CTC does not support bridge and roll on circuits
having multiple cross-connects on a single node.
EID-5095
No path were selected.
Please select at least one path starting from the {0} NE.
EID-5096
The first path must starts from the {0} NE.
EID-5097
The selected path should be linked with the last selected and
keep the same direction.
EID-5098
The node is not selectable.
Only the Span between the nodes are selectable.
EID-5099
Raman Command Error on {0}.
{1}.
EID-5100
Raman Command in TimeOut.
{0}.
Cisco ONS 15310-MA SDH Troubleshooting Guide, Release 9.1 and Release 9.2
4-40
Chapter 4
Description
Refer to the error message text.
During an RPR circuit creation ML card,
the new circuit size and the existing circuit
size must be the same.
The trunk specified is not found.
Refer to the error message.
Refer to the error message.
Refer to the error message text.
Refer to the error message text.
Refer to the error message text
Refer to the error message text
Refer to the error message text
Confirm if you really want to modify TL1
tunnel encoding.
Refer to the error message text.
Refer to the error message text.
Refer to the error message text.
Refer to the error message text.
Refer to the error message text.
Refer to the error message text.
Refer to the error message text.
Error Messages