Error Messages
Table 4-1
Error Messages (continued)
Error/Warning
ID
Error/Warning Message
EID-3262
The port provisioning cannot be changed when the port status
is {0}.
WID-3263
You are using Java version {0}. CTC should run with Java
version {1}. It can be obtained from the installation CD or
http://java.sun.com/j2se/
EID-3265
An error occurred while modifying the protection group.
EID-3266
Conditions could not be retrieved from the shelf or card view.
WID-3267
The XTC protection group cannot be modified.
WID-3268
The filter entry is invalid. {0}
WID-3269
The {0} operation was successfully initiated for {1} but its
completion status could not be obtained from the node. When
the node is accessible, check its software version to verify if the
{0} succeeded.
WID-3270
The file {0} does not exist.
WID-3271
The value entered must be greater than {0}.
WID-3272
An entry is required.
WID-3273
{0} already exists in the list.
WID-3274
A software upgrade is in progress.
Network configuration changes that result in a node reboot
cannot take place during a software upgrade.
Please try again after the software upgrade is done.
WID-3275
Ensure that the remote interface ID and the local interface ID
on the two sides match.
(The local interface ID on this node should equal the remote
interface ID on the neighbor node and vice-versa).
WID-3276
Both {0} and {1} exist on the same selected port.
{2}
WID-3277
The description cannot exceed {0} characters. Your input will
be truncated.
WID-3279
This card has been deleted. CTC will return to the shelf view.
WID-3280
ALS will not engage until both the protected trunk ports detect
LOS.
WID-3282
Performing a software upgrade while TSC 5 is active could
result in a service disruption. It is recommended that you make
TSC 10 the active TSC by performing a soft reset of TSC 5. The
following ONS 15600s are currently unsafe to upgrade...
78-19418-01
Cisco ONS 15310-MA SDH Troubleshooting Guide, Release 9.1 and Release 9.2
Description
You must provision the ports only when the
port is Out of Service.
CTC is being launched with the wrong
version of the JRE {0}. This version of CTC
requires a particular version of the JRE {1}.
The CTC and browser must be closed and
restarted to allow the correct Java version to
be loaded.
Protection Group could not be modified.
Refer to the error message text.
Refer to the warning message text.
The specified entry is invalid.
Refer to the error message text.
The specified file does not exist.
The value entered must be greater than the
specified value.
An entry is required to complete this task.
The specified item already exists in the list.
Refer to the warning message text.
Refer to the warning message text.
The specified port has both RS-DCC and
MS-DCC.
The input exceeds the character limit. The
value will be truncated to the maximum
character limit.
CTC returns to node view.
Refer to the warning message text.
Refer to the warning message text.
4-27