Cisco ONS 15454 Troubleshooting Manual page 18

Hide thumbs Also See for ONS 15454:

Advertisement

Table 4-1
Error Messages (continued)
Error/Warning
ID
Error/Warning Message
EID-3047
The file {0} could not be read.
Please verify the name and try again.
EID-3048
There is no Cisco IOS startup configuration file available to
download.
EID-3049
The download cannot be done at this time because an update in
progress.
EID-3050
An error occurred while trying to save the file to your local file
system.
EID-3051
The configuration file has a maximum size of {0} bytes.
EID-3052
An error occurred while saving the configuration file to the
TCC2/TCC2P.
EID-3053
The value of {0} must be between {1} and {2}.
EID-3054
The provisioned input/output ports cannot be removed or
another user is updating the card. Please try to remove these
ports later.
EID-3055
The soak maintenance pane cannot be created.
EID-3056
Defaults cannot be saved to the file {0}.
EID-3057
Default properties cannot be loaded from the node.
EID-3058
The file {0} does not exist.
EID-3059
An error occurred while refreshing.
EID-3060
The ALS recovery pulse interval must be between {0} seconds
and {1} seconds.
EID-3061
The ALS recovery pulse duration must be between {0} seconds
and {1} seconds.
EID-3062
An error occurred while setting values in the table.
EID-3064
This is not a G1000 card.
EID-3065
An error occurred while attempting to create this RMON
threshold:
{0}
EID-3066
The sample period must be between 10 and {0}.
EID-3067
The rising threshold must be between 1 and {0}.
EID-3068
The falling threshold must be between 1 and {0}.
Cisco ONS 15310-MA SDH Troubleshooting Guide, Release 9.1 and Release 9.2
4-18
Chapter 4
Description
Refer to the error message text.
CTC could not find the configuration file
for IOS startup.
Refer to the error message text.
Check whether the file already exists and
cannot be over written, or there is a space
constraint in the file system.
The size of the configuration file should not
exceed the specified number of bytes.
Refer to the error message text.
The value of the item must be between the
specified values.
Another user may be updating the card. You
can try again later.
Refer to the error message text.
CTC cannot save the defaults to the
specified file.
Refer to the error message text.
Refer to the error message text.
There was an error while refreshing.
The automatic laser shutdown (ALS)
Recovery Interval must be between the
specified range of seconds.
The automatic laser shutdown (ALS)
Recovery Duration must be between the
specified range of seconds.
Refer to the error message text.
This card is not a G1000-4 card.
You must wait some time before you try
again.
Refer to the error message text.
This is an invalid rising threshold entry. The
valid range is from 1 to the specified value.
This is an invalid falling threshold entry.
The valid range is from 1 to the specified
value.
Error Messages
78-19418-01