3. Either:
Press the red
reset button
Toggle the reset digital input, or
Carry out a drive reset through serial communications by
setting Pr 10.38 to 100 (ensure that Pr. xx.00 returns to 0).
5.10
Differences between European and
USA defaults
Pr
Description
2.06
S ramp enable
Tachometer voltage rating
3.51
(Fb02, 0.72)
5.09,
Armature rated voltage
21.09
(SE06, 0.27)
Field weakening
5.28
compensation disable
5.59,
Back emf set point
21.08
5.65
Economy timeout
5.70,
Rated field current
21.24
(SE10, 0.31)
5.73,
Rated field voltage
21.23
(SE11, 0.32)
5.75
Field voltage mode
Analog input 3 mode
7.15
(in01, 0.81)
5.11
Displaying parameters with non-
default values only
Select dIS.dEf in Pr xx.00, the only parameters that will be visible to the
user will be those containing a non-default value. This function does not
require a drive reset to become active. To deactivate this function, return
to Pr xx.00 and enter a value of 0.
Please note that this function can be affected by the access level
enabled. You must refer to section 5.13 Parameter access level and
security for more information regarding access level.
5.12
Displaying destination parameters
only
Select dIS.dESt in Pr xx.00, the only parameters that will be visible to
the user will be destination parameters. This function does not require a
drive reset to become active. To deactivate this function, return to
Pr xx.00 and enter a value of 0.
Please note that this function can be affected by the access level
enabled You must refer to section 5.13 Parameter access level and
security for further information regarding access levels.
5.13

Parameter access level and security

The parameter access levels determine whether the user has access to
Menu 0 (in sub block mode) only or to all of the advanced menus (Menus
1 to 23), in addition to Menu 0 (in linear mode).
The user security determines whether the access to the user is read only
or read write.
The user security and the parameter access level can operate
independently of each other as shown in Table 5-5 .
62
Electrical
Getting
Basic
installation
started
parameters
Default
Eur: OFF (0), USA: On (1)
Eur: 60.00, USA: 50.00
480V drive Eur: 440, USA:500
Eur: OFF (0), USA On (1)
480V drive Eur: 440, USA:500
Eur: OFF (0), USA: On (1)
Size 1: Eur: 2.00, USA: 8.00
Size 2A & B Eur: 3.00, USA:
20.00 Size 2C & D Eur: 5.00,
USA 20.00
Eur: 360, USA: 300
Eur: OFF (0), USA: On (1)
Eur: th (8), USA: VOLt (6)
www.controltechniques.com
Running the
SMARTCARD
Optimization
motor
operation

Table 5-5 User security and parameter access levels

Parameter
access level
L1
L1
L2
L2
RW = Read / write access
The default settings of the drive are parameter access level L1 and User
Security Open, i.e. read / write access to Menu 0 with the advanced
menus, not visible
5.13.1
User security
The user security, when set, prevents write access to any of the
parameters (other than Pr 11.44 (SE14, 0.35) Access Level) in any menu.

Figure 5-8 User security open

User security open - All parameters: Read / Write access
Pr 0.00
Pr 1.00
Pr 0.01
Pr 1.01
Pr 0.02
Pr 1.02
Pr 0.03
Pr 1.03
Pr 0.89
Pr 1.50
Pr 0.90
Pr 1.51
User security closed - All parameters: Read Only access
Pr 0.00
Pr 1.00
Pr 0.01
Pr 1.01
Pr 0.02
Pr 1.02
Pr 0.03
Pr 1.03
Pr 0.49
Pr 1.50
Pr 0.90
Pr 1.51
5.13.2
Setting user security
Enter a value between 1 and 999 in Pr 11.30 and press the
the security code has now been set to this value. To activate the security,
the access level must be set to Loc in Pr 11.44 (SE14, 0.35). When the
drive is reset, the security code will have been activated and the drive
returns to access level L1. The value of Pr 11.30 will return to 0 in order
to hide the security code. At this point, the only parameter that can be
changed by the user is the access level Pr 11.44 (SE14, 0.35).
5.13.3
Unlocking user security
Select a read write parameter to be edited and press the
upper display will now show CodE.
Use the arrow buttons to set the security code and press the
With the correct security code entered, the display will revert to the
parameter selected in edit mode. If an incorrect security code is entered
the display will revert to parameter view mode.
To lock the user security again, set Pr 11.44 (SE14, 0.35) to Loc and
press the
reset button.
Onboard
Advanced
Technical
PLC
parameters
data
User security
Menu 0 status
Open
Sub block RW
Closed
Sub block RO
Open
Linear RW
Closed
Linear RO
RO = Read only access
............
Pr 22.00
............
Pr 22.01
............
Pr 22.02
............
Pr 22.03
............
............
............
Pr 22.39
............
Pr 22.40
(except Pr
11.44 SE14, 0.35
(
............
Pr 22.00
............
Pr 22.01
............
Pr 22.02
............
Pr 22.03
............
............
............
Pr 22.39
............
Pr 22.40
Mentor MP User Guide
UL
Diagnostics
information
Advanced
menus status
Not visible
Not visible
RW
RO
Pr 23.00
Pr 23.01
Pr 23.02
Pr 23.03
Pr 23.10
Pr 23.11
)
Pr 23.00
Pr 23.01
Pr 23.02
Pr 23.03
Pr 23.10
Pr 23.11
button;
button; the
button.
Issue: 3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents