Table 12-31 Siba Semiconductor Fusing For 480V And 575V Size 1 Drives; Table 12-32 Siba Branch Circuit Protection Fusing For 480V And 575V Size 1 Drives; Table 12-33 Siba Dc Protection Fusing For 480V And 575V Size 1 Drives - Emerson MP25A4 User Manual

Mentor mp series high performance dc drive 25a to 7400a, 480v to 690v two or four quadrant operation
Table of Contents

Advertisement

Safety
Product
Mechanical
Information
information
Installation

Table 12-31 Siba semiconductor fusing for 480V and 575V size 1 drives

Model
Auxiliary
MP25A4
MP25A5
MP45A4
MP45A5
MP75A4
MP75A5
MP25A4(R)
MP25A5(R)
MP45A4(R)
MP45A5(R)
MP75A4(R)
MP75A5(R)
MP105A4
MP105A5
MP155A4
MP155A5
MP210A4
MP210A5
MP105A4(R) MP105A5(R)
MP155A4(R) MP155A5(R)
MP210A4(R) MP210A5(R)

Table 12-32 Siba branch circuit protection fusing for 480V and 575V size 1 drives

Model
Auxiliary
MP25A4
MP25A5
MP45A4
MP45A5
MP75A4
MP75A5
MP25A4(R)
MP25A5(R)
MP45A4(R)
MP45A5(R)
MP75A4(R)
MP75A5(R)
MP105A4
MP105A5
MP155A4
MP155A5
MP210A4
MP210A5
MP105A4(R)
MP105A5(R)
MP155A4(R)
MP155A5(R)
MP210A4(R)
MP210A5(R)

Table 12-33 Siba DC protection fusing for 480V and 575V size 1 drives

Model
MP25A4R
MP25A5R
MP45A4R
MP45A5R
MP75A4R
MP75A5R
MP105A4R
MP105A5R
MP155A4R
MP155A5R
MP210A4R
MP210A5R
NOTE
DC protection fusing is only required for 4 quadrant drives.
Mentor MP User Guide
Issue: 3
Electrical
Getting
Basic
installation
started
parameters
Rating
Fuse type
V
10 x 38mm ferrule
660Vac
22 x 58mm ferrule
690Vac
Size 000 square
body
Rating
Fuse type
NH 000 knife blade
NH 00 knife blade
NH 000 knife blade
NH 00 knife blade
690Vac
NH 1 knife blade
NH 2 knife blade
NH 1 knife blade
NH 2 knife blade
Rating
Fuse type
20 x 127mm cylindrical
1000Vdc
36 x 190mm cylindrical
1500Vdc
SQB-DC2 square body
900Vdc
www.controltechniques.com
Running the
SMARTCARD
Optimization
motor
operation
Rating
Description
A
12
10 x 38 cylindrical 660Vac URZ
32
63
100
22 x 58 cylindrical 690Vac URZ
32
63
100
160
URB 000 690Vac 160A bolt-type
200
URB 000 690Vac 200A bolt-type
315
URB 000 690Vac 315A bolt-type
160
URB 000 690Vac 160A bolt-type
200
URB 000 690Vac 200A bolt-type
315
URB 000 690Vac 315A bolt-type
Rating
V
A
10
NH 000 gG 690Vac 10A
35
NH 000 gG 690Vac 35A
63
NH 00 gG 690Vac 63A
100
NH 00 gG 690Vac 100A
35
NH 000 gG 690Vac 35A
63
NH 00 gG 690Vac 63A
100
NH 00 gG 690Vac 100A
160
NH1 gG 690Vac 160A
200
NH1 gG 690Vac 200A
315
NH2 gG 690Vac 315A
160
NH1 gG 690Vac 160A
200
NH1 gG 690Vac 200A
315
NH2 gG 690Vac 315A
Rating
Description
V
A
32
20 x 127 1000Vdc 32A gR
50
20 x 127 1000Vdc 50A gR
80
36 x 190 1500Vdc 80A gR
125
SQB-DC2 1200V 125A
160
SQB-DC2 1200V 160A
250
SQB-DC2 1200V 250A
Onboard
Advanced
Technical
PLC
parameters
data
Part number
(with indicator)
50 179 06.12
50 140 06.32
50 140 06.63
50 140 06.100
50 140 06.32
50 140 06.63
50 140 06.100
20 282 20.160
20 282 20.200
20 282 20.315
20 282 20.160
20 282 20.200
20 282 20.315
Description
Ref number
90 080 10.32
90 080 10.50
90 094 10.80
90 203 25.125
90 203 25.160
90 203 25.250
UL
Diagnostics
information
Part number
(without
indicator)
20 282 21.160
20 282 21.200
20 282 21.315
20 282 21.160
20 282 21.200
20 282 21.315
Part number
20 477 13.10
20 477 13.35
20 209 13.63
20 209 13.100
20 477 13.35
20 209 13.63
20 209 13.100
20 211 13.160
20 211 13.200
20 212 13.315
20 211 13.160
20 211 13.200
20 212 13.315
Configuration
single fuse
single fuse
single fuse
single fuse
single fuse
single fuse
161

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents