Installation
3.4
Mounting method
The Mentor MP can only be surface mounted.
If the drive has been used at high load levels for a period of
time, the heatsink can reach temperatures in excess of 70°C
(158°F). Human contact with the heatsink should be
prevented.
WARNING
Many of the drives in this product range weigh in excess of
15kg (33lb). Use appropriate safeguards when lifting these
models.
WARNING
Figure 3-5 Overall size 1A dimensions
293mm (11.54in)
250mm (9.84in)
MA1
MA2
95mm
(3.74in)
1. The two outer holes must be used for mounting the Mentor MP.
NOTE
With the SMARTCARD installed to the drive, the depth measurement
increases by 7.6mm (0.30 in).
NOTE
Fans are only installed to the MP75A4(R) and MP75A5(R).
Mentor MP User Guide
Issue: 3
Electrical
Getting
Basic
installation
started
parameters
1
444mm
(17.48in)
1
222mm
(8.74in)
www.controltechniques.com
Running the
SMARTCARD
Optimization
motor
operation
222mm (8.74in)
1
1
Onboard
Advanced
Technical
PLC
parameters
data
170mm (6.69in)
6.5mm (0.26in)
22mm
(0.87in)
40mm
(1.58in)
250mm (9.84in)
UL
Diagnostics
information
4 holes to
suit M6
380mm
(14.96in)
17