Starting Frequency And Start-Time Hold Function (Pr.13, Pr.571) - Mitsubishi Electric F700 Instruction Manual

Hide thumbs Also See for F700:
Table of Contents

Advertisement

Setting of acceleration/deceleration
time and acceleration/deceleration
3.6.2

Starting frequency and start-time hold function (Pr.13, Pr.571)

You can set the starting frequency and hold the set starting frequency for a certain period of time.
Pr.12
Set these functions when you need the starting torque or want to smooth motor drive at a start.
page 81
Pr.14
page 60
Parameter
Pr.570
Number
page 61
Pr.575
page 184
13
Starting frequency
571
Holding time at a start
The above parameters can be set when Pr. 160 User group read selection = "0". (Refer to page 140)
Output
frequency
(Hz)
60
Pr.13
0
Forward
rotation
CAUTION
The inverter will not start if the frequency setting signal is less than the value set in Pr. 13.
For example, when 5Hz is set in Pr. 13, the motor will not start running until the frequency setting signal reaches 5Hz.
Output
frequency
(Hz)
60
Pr.13
0
Pr.571 setting time
Forward
rotation
CAUTION
⋅ When the start signal was turned off during start-time hold, deceleration is started at that point.
⋅ At switching between forward rotation and reverse rotation, the starting frequency is valid but the start-time hold function is
invalid.
Note that when Pr. 13 is set to any value lower than Pr. 2 Minimum frequency, simply turning on the start signal
will run the motor at the preset frequency even if the command frequency is not input.
♦ Parameters referred to ♦
Pr.2 Minimum frequency
76
Name
Time
ON
Time
ON
Refer to page 62
Initial Value
Setting Range
0.5Hz
0 to 60Hz
0.0 to 10.0s
9999
9999
(1) Starting frequency setting (Pr.13)
⋅ Frequency at start can be set in the range 0 to 60Hz.
⋅ You can set the starting frequency at which the start signal is
turned on.
(2) Start-time hold function (Pr.571)
⋅ This function holds the time set in Pr. 571 and the output
frequency set in Pr. 13 Starting frequency.
⋅ This function performs initial excitation to smooth the motor
drive at a start.
REMARKS
When Pr. 13 = "0Hz", the starting frequency is held at 0.01Hz.
Caution
Description
Frequency at start can be set in the
range 0 to 60Hz.
You can set the starting frequency
at which the start signal is turned
on.
Set the holding time of Pr. 13
Starting frequency.
Holding function at a start is invalid

Hide quick links:

Advertisement

Table of Contents
loading