Mitsubishi Electric F700 Instruction Manual page 179

Hide thumbs Also See for F700:
Table of Contents

Advertisement

Communication operation and setting
[Run command]
Instruction
Item
Code
Length
Run
HFA
command
Run
command
HF9
16bit
(extended)
*1
The signal within parentheses is the initial setting. The description changes depending on the setting of Pr. 180 to Pr. 189 (input terminal function
selection) (page85).
*2
The signal within parentheses is the initial setting. Since jog operation/selection of automatic restart after instantaneous power failure/start
self-holding/reset cannot be controlled by the network, bit 8 to bit 11 are invalid in the initial status. When using bit 8 to bit 11, change the
signals with Pr. 185, Pr. 186, Pr. 188, Pr. 189 (input terminal function selection) (page 91). (Reset can be executed with the instruction code HFD.)
[Inverter status monitor]
Instruction
Item
Code
Length
Inverter
status
H7A
monitor
Inverter
status
H79
monitor
(extended)
* The signal within parentheses is the initial setting. The description changes depending on the setting of Pr. 190 to Pr. 196 (output terminal function
selection).
172
Bit
Description
b0: AU (current input selection)
b1: Forward rotation command
b2: Reverse rotation command
b3: RL (low speed operation
command)
*1
8bit
b4: RM (middle speed operation
command)
*1
b5: RH (high speed operation
command)
*1
b6: RT (second function selection)
b7: MRS (output stop)
b0:AU (current input selection)
b1:Forward rotation command
b2:Reverse rotation command
b3:RL (low speed operation
command)
*1
b4:RM (middle speed operation
command)
*1
b5: RH (high speed operation
command)
*1
b6:RT (second function selection)
b7:MRS (output stop)
b8:JOG (Jog operation)
b9:CS (selection of automatic restart
after instantaneous power failure)
b10: STOP (start self-holding)
b11:RES (reset)
*2
b12:
b13:
b14:
b15:
Bit
Description
b0:RUN (inverter running)*
b1:Forward rotation
b2:Reverse rotation
b3:SU (up to frequency) *
8bit
b4:OL (overload) *
b5:IPF (instantaneous power failure) *
b6:FU (frequency detection)*
b7:ABC1 (alarm) *
b0:RUN (inverter running) *
b1:Forward rotation
b2:Reverse rotation
b3:SU (up to frequency) *
b4:OL (overload) *
b5:IPF (instantaneous power failure) *
b6:FU (frequency detection) *
b7:ABC1 (alarm) *
16bit
b8:ABC2 ()*
b9:
b10:
b11:
b12:
b13:
b14:
b15: Alarm occurrence
*1
*1
*1
*1
[Example 1] H0002 Forward rotation
b15
0
0
0
*1
*1
[Example 2] H0800 low speed operation
(When Pr. 189 RES terminal function selection is set to "0")
*2
b15
*2
0
0
0
*2
[Example 1] H0002
b15
0
0
0
[Example 2] H8080
b15
1
0
0
Example
[Example 1] H02 Forward rotation
b7
b0
0
0
0
0
0
0
1
0
[Example 2] H00 Stop
b7
b0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
0
Example
[Example 1] H02
During forward
rotation
b7
0
0
0
0
0
0
1
[Example 2] H80
Stop at alarm
occurrence
b7
0
0
0
0
0
0
1
During forward rotation
0
0
0
0
0
0
0
0
Stop at alarm occurrence
0
0
0
0
0
1
0
0
b0
0
0
1
0
b0
0
0
0
0
b0
0
b0
0
b0
0
0
0
1
0
b0
0
0
0
0
0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents