Mitsubishi Electric F700 Instruction Manual page 178

Hide thumbs Also See for F700:
Table of Contents

Advertisement

[Special monitor selection No.]
Refer to page 100 for details of the monitor description.
Data
Description
H01
Output frequency
H02
Output current
H03
Output voltage
H05
Frequency setting
H06
Running speed
H08
Converter output voltage
H09
Regenerative brake duty
Electronic thermal relay function
H0A
load factor
H0B Output current peak value
Converter output voltage peak
H0C
value
H0D Input power
*1
Input terminal monitor details
b15
*2
Output terminal monitor details
b15
*3
The setting depends on capacities. (01160 or less/01800 or more)
[Alarm data]
Refer to page 228 for details of alarm description.
Data
Description
Data
Description
H00
No alarm
H60
H10
OC1
H70
H11
OC2
H80
H12
OC3
H81
H20
OV1
H90
H21
OV2
H91
H22
OV3
HA0
H30
THT
HA1
H31
THM
HB0
H40
FIN
HB1
H50
IPF
HB2
H51
UVT
HB3
H52
ILF
HC0
Unit
0.01Hz
0.01A/0.1A
*3
0.1V
0.01Hz
1r/min
0.1V
0.1%
0.1%
0.01A/0.1A
*3
0.1V
0.01kWh/
0.1kWh
*3
CS
RES
STOP
MRS
Data
Description
OLT
HC1
CTE
BE
HC2
P24
GF
HC4
CDO
LF
HC5
IOH
OHT
HC6
SER
PTC
HC7
AIE
OPT
HF1
E.1
OP1
HF6
E.6
PE
HF7
E.7
PUE
HFD
E.13
RET
PE2
CPU
Communication operation and setting
Data
Description
H0E Output power
H0F
Input terminal status
H10
Output terminal status
H11
Load meter
H14
Cumulative energization time
H17
Actual operation time
H18
Motor load factor
H19
Cumulative power
H32
Power saving effect
H33
Cumulative saving power
H34
PID set point
H35
PID measurement value
H36
PID deviation value
JOG
RH
RM
ABC2
ABC1
Alarm description display example (instruction code H74)
For read data H30A0
(Previous alarm ...... THT)
b15
(Latest alarm ...... OPT)
0
0
1
Previous alarm
(H30)
Unit
0.01kWh/
0.1kWh
*3
*1
*2
0.1%
1h
1h
0.1%
1kWh
Variable
Variable
0.1%
0.1%
0.1%
RL
RT
AU
STR
FU
OL
IPF
SU
b8 b7
b0
1 0 0 0 0
1
0
1
0
0
0
0
0
Latest alarm
(HA0)
b0
STF
b0
RUN
3
171

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents