(3) Minor fault
When the protective function is activated, the output is not shut off. You can also output a minor fault signal by
making parameter setting. (Set "98" in any of Pr. 190 to Pr. 196 (output terminal function selection). (Refer to page
.))
91
Operation Panel
Indication
Name
Fan fault
For the inverter that contains a cooling fan,
Description
fan stops due to a fault or different operation from the setting of Pr. 244 Cooling fan operation
selection.
Check point
Check the cooling fan for a fault.
Corrective action
Check for fan fault. Please contact your sales representative.
(4) Major fault
When the protective function is activated, the inverter output is shut off and an alarm is output.
Operation Panel
Indication
Name
Overcurrent shut-off during acceleration
When the inverter output current reaches or exceeds approximately 170% of the rated current during
Description
acceleration, the protective circuit is activated to stop the inverter output.
1. Check for sudden acceleration.
2. Check that the downward acceleration time is not long in vertical lift application.
3. Check for output short circuit.
Check point
4. Check that stall prevention operation is correct
5. Check that the regeneration is not performed frequently. (Check that the output voltage becomes
1. Increase the acceleration time.
2. When "E.OC1" is always lit at starting, disconnect the motor once and start the inverter.
Corrective action
3. Check the wiring to avoid output short circuit.
4. Perform a correct stall prevention operation. (Refer to page 64.)
5. Set base voltage (rated voltage of the motor, etc.) in Pr. 19 Base frequency voltage. (Refer to page
Operation Panel
Indication
Name
Overcurrent shut-off during constant speed
When the inverter output current reaches or exceeds approximately 170% of the rated current
Description
during constant speed operation, the protective circuit is activated to stop the inverter output.
1. Check for sudden load change.
Check point
2. Check for output short circuit.
3. Check that stall prevention operation is correct
1. Keep load stable.
Corrective action
2. Check the wiring to avoid output short circuit.
3. Check that stall prevention operation setting is correct. (Refer to page 56.)
Operation Panel
Indication
Name
Overcurrent shut-off during deceleration or stop
When the inverter output current reaches or exceeds approximately 170% of the rated inverter
Description
current during deceleration (other than acceleration or constant speed), the protective circuit is
activated to stop the inverter output.
1. Check for sudden speed reduction.
2. Check for output short circuit.
Check point
3. Check for too fast operation of the motor's mechanical brake.
4. Check that stall prevention operation setting is correct.
1. Increase the deceleration time.
2. Check the wiring to avoid output short circuit.
Corrective action
3. Check the mechanical brake operation.
4. Check that stall prevention operation setting is correct. (Refer to page 56.)
FN
E.OC1
larger than the reference voltage at regeneration and overcurrent due to increase in motor
current occurs.)
(Shorten the downward acceleration time in vertical lift application.)
If "E.OC1" is still lit, contact your sales representative.
56.)
E.OC2
E.OC3
Causes and corrective actions
FR-PU04
FN
appears on the operation panel when the cooling
FR-PU04
OC During Accs
FR-PU04
Stedy Spd OC
FR-PU04
OC During Dec
4
233