Selection of operation mode and
operation location
(5) Selection of control source in network operation mode (Pr. 338, Pr. 339)
⋅ As control sources, there are the operation command sources that control the signals related to the inverter
start command and function selection and the speed command source that controls the signals related to
frequency setting.
⋅ In network operation mode, the commands from the external terminals and communication (inverter RS-485
terminals or communication option) are as listed below.
Pr. 338 Communication operation
Operation
command source
Location
Pr. 339 Communication speed command
Selection
Running frequency from
Fixed function
communication
(Terminal-
Terminal 2
equivalent
Terminal 4
function)
Terminal 1
Low speed operation command/
0
RL
remote setting clear
Middle-speed operation command/
1
RM
remote setting deceleration
High speed operation command/
2
RH
remote setting acceleration
3
RT
Second function selection
4
AU
Terminal 4 input selection
5
JOG Jog operation selection
Selection of automatic restart
6
CS
after instantaneous power failure
7
OH External thermal relay input
8
REX Fifteen speed selection
10
X10 Inverter operation enable signal
FR-HC or MT-HC connection,
11
X11
instantaneous power failure
detection
12
X12 PU operation external interlock
External DC injection brake
13
X13
operation is started
14
X14 PID control valid terminal
PU-external operation
16
X16
switchover
Output stop
24
MRS
PU operation interlock
25
STOP Start self-holding selection
37
X37 Traverse function selection
60
STF Forward rotation command
61
STR Reverse rotation command
62
RES Reset
63
PTC PID forward action switching
64
X64 PID forward action switching
65
X65 PU-NET operation switching
66
X66 NET-external operation switching
67
X67 Command source switchover
[Explanation of table]
External
: Operation is valid only from external terminal signal.
NET
: Control only from communication is valid
Combined
: Operation is valid from either of external terminal and communication.
: Operation is invalid from either of external terminal and communication.
Compensation :Control only from external terminal signals is valid when Pr. 28 Multi-speed input compensation selection = "1"
REMARKS
⋅ The control source of communication is as set in Pr. 550 and Pr. 551.
154
0: NET
source
NET
NET
NET
NET
NET
NET
NET
0: NET
1: External
1:
2:
0: NET
External
External
NET
NET
External
External
Compensation
External
NET
External
NET
External
NET
NET
Combined
External
External
External
NET
External
External
External
NET
External
NET
External
Combined
External
NET
NET
NET
External
External
External
NET
External
External
External
Remarks
1:
2:
External
External
NET
External
External
External
Pr. 59 = "0" (multi-
speeds)
External
Pr. 59 = "1 , 2"
(remote)
External
External
Combined
External
Pr. 59 = "0"
External
(multi-speeds)
External
External
External
Pr. 79
Pr. 79 = "7"
When X12 signal
is not assigned
External
External
External
External
External
"7"

Hide quick links: