(1) Operation mode basics
PU operation
mode
Inverter
Network operation mode
RS-485
terminal
Communication
option
External terminal
REMARKS
⋅ Either "3" or "4" may be set to select the PU/external combined operation, and these settings differ in starting method.
⋅ In the initial setting, the stop function by
operation mode. (Pr. 75 Reset selection/disconnected PU detection/PU stop selection. Refer to page 136.)
(2) Operation mode switching method
When "0, 1, or 2" is set in Pr. 340
Switching from the network
Switch to the external
operation mode from
the network.
Network operation
When "10 or 12" is set in Pr. 340
Network operation
REMARKS
⋅ For switching of operation by external terminals, refer to the following:
PU operation external interlock signal (X12 signal)
PU-external operation switch-over signal (X16)
External-NET operation switchover signal (X65), NET-PU operation switchover signal (X66)
Pr. 340 Communication startup mode selection
Operation
panel
Personnel
computer
Personnel
PLC
computer
Network operation
mode
5 6
4
3
7
2
8
1
9
External
10
operation
Volume
Switch
mode
of the PU (FR-DU07) (PU stop selection) is valid also in other than the PU
External operation
Switch to the network operation
mode from the network.
Press
of the PU to light
Press
of the PU to light
. page 147
page 148
page 150
Selection of operation mode and
⋅ The operation mode is to specify the source of
inputting the start command and set frequency of
the inverter.
⋅ Select the "external operation mode" when
performing operation by basically using the
control
circuit
terminals
potentiometers, switches, etc. externally, select
the "PU operation mode" when inputting the start
command
and
frequency
communication from the operation panel (FR-
DU07),
parameter
unit
connector, or select the "network operation
mode (NET operation mode)" when using the
RS-485 terminals or communication option.
⋅ The operation mode can be selected from the
operation panel or with the communication
instruction code.
Switching from the PU
Press
of
the PU to light
page 149
operation location
and
providing
setting
through
(FR-PU04),
PU
Press
of
the PU to light
PU operation
PU operation
143
3