Communication operation and setting
(6) Modbus registers
System environment variable
Register
40002
Inverter reset
40003
Parameter clear
40004
All parameter clear
40006
Parameter clear
40007
All parameter clear
40009
Inverter status/control input instruction
40010
Operation mode/inverter setting
40014
Running frequency (RAM value)
40015
Running frequency (EEPROM value)
*1
The communication parameter values are not cleared.
*2
For write, set the data as a control input instruction. For read, data is read as an inverter operating status.
*3
For write, set data as the operation mode setting. For read, data is read as the operation mode status.
<Inverter status/control input instruction>
Bit
Control input instruction
0
Stop command
1
Forward rotation command
2
Reverse rotation command
3
RH (high speed operation command)
4
RM (middle speed operation command)
5
RL (low speed operation command)
6
JOG (Jog operation)
7
RT (second function selection)
8
AU (current input selection)
9
(selection of automatic restart after
instantaneous power failure)
10
MRS (output stop)
11
STOP (start self-holding)
12
RES (reset)
13
14
15
*1
The signal within parentheses is the initial setting. The description changes depending on the setting of Pr. 180 to Pr. 189 (input
terminal function selection) (page85).
Each assigned signal is valid or invalid depending on NET. (Refer to page 151)
*2
The signal within parentheses is the initial setting. The description changes depending on the setting of Pr. 190 to Pr. 196 (output
terminal function selection) (page91).
Real-time monitor
Refer to page 100 for details of the monitor description.
Register
Description
40201
Output frequency
40202
Output current
40203
Output voltage
40205
Frequency setting
40206
Running speed
40208
Converter output voltage
40209
Regenerative brake duty
Electronic thermal relay function
40210
load factor
40211
Output current peak value
40212
Converter output voltage peak value
40213
Input power
*1
Input terminal monitor details
b15
*2
Output terminal monitor details
b15
*3
The setting depends on capacities. (01160 or less/01800 or more)
182
Definition
*1
*1
*3
Definition
*1
*1
IPF (instantaneous power failure)
*1
*1
*1
*1
CS
*1
*1
*1
*1
0
0
0
Unit
0.01Hz
0.01A/0.1A
0.1V
0.01Hz
1r/min
0.1V
0.1%
0.1%
0.01A/0.1A
0.1V
0.01kWh/
0.1kWh
CS
RES
STOP
Read/write
Write
Any value can be written
Write
Set H965A as a written value.
Write
Set H99AA as a written value.
Write
Set H5A96 as a written value.
Write
Set HAA99 as a written value.
Read/write
See below.
*2
Read/write
See below.
Read/write
According to the Pr. 37 and Pr. 144 settings,
the frequency and selectable speed are in
Write
1r/min increments.
Inverter status
RUN (inverter running)
*2
Forward rotation
Reverse rotation
SU (up to frequency)
*2
OL (overload)
*2
FU (frequency detection)
*2
ABC1 (alarm)
*2
)
ABC2 (
*2
0
0
0
0
0
0
Alarm occurrence
Register
40214
Output power
*3
40215
Input terminal status
40216
Output terminal status
40217
Load meter
40220
Cumulative energization time
40223
Actual operation time
40224
Motor load factor
40225
Cumulative power
40250
Power saving effect
*3
40251
Cumulative saving power
40252
PID set point
40253
PID measurement value
*3
40254
PID deviation value
MRS
JOG
RH
RM
ABC2
ABC1
Remarks
<Operation mode/inverter setting>
Read
Mode
value
EXT
H0000
PU
H0001
EXT
H0002
JOG
NET
H0004
*2
PU+
H0005
EXT
The restrictions depending on the
operation mode changes according
to the computer link specifications.
Description
*1
*2
RL
RT
AU
FU
OL
IPF
Written
value
H0010
H0014
Unit
0.01kWh/
0.1kWh
*3
0.1%
1h
1h
0.1%
1kWh
Variable
Variable
0.1%
0.1%
0.1%
b0
STR
STF
b0
SU
RUN