GE T60 Instruction Manual page 615

Ur series transformer protection system
Hide thumbs Also See for T60:
Table of Contents

Advertisement

APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 11 of 73)
ADDR
REGISTER NAME
2197
Breaker Flashover 1 Side 1 Source
2198
Breaker Flashover 1 Side 2 Source
2199
Breaker Flashover 1 Status Closed A
219B
Breaker Flashover 1 Status Closed B
219D
Breaker Flashover 1 Status Closed C
219F
Breaker Flashover 1 Voltage Pickup Level
21A0
Breaker Flashover 1 Voltage Difference Pickup Level
21A2
Breaker Flashover 1 Current Pickup Level
21A3
Breaker Flashover 1 Pickup Delay
21A4
Breaker Flashover 1 Supervision Phase A
21A6
Breaker Flashover 1 Supervision Phase B
21A8
Breaker Flashover 1 Supervision Phase C
21AA
Breaker Flashover 1 Block
21AC
Breaker Flashover 1 Events
21AD
Breaker Flashover 1 Target
21AE
Reserved (4 items)
21B2
...Repeated for Breaker Flashover 2
Breaker Arcing Current Actual Values (Read Only Non-Volatile) (4 modules)
21E0
Breaker 1 Arcing Current Phase A
21E2
Breaker 1 Arcing Current Phase B
Breaker Arcing Current Actual Values (Read Only Non-Volatile) (4 modules)
21E4
Breaker 1 Arcing Current Phase C
Breaker Arcing Current Actual Values (Read Only Non-Volatile) (4 modules)
21E6
Breaker 1 Operating Time Phase A
21E7
Breaker 1 Operating Time Phase B
Breaker Arcing Current Actual Values (Read Only Non-Volatile) (4 modules)
21E8
Breaker 1 Operating Time Phase C
21E9
Breaker 1 Operating Time
21EA
...Repeated for module number 2
Breaker Arcing Current Actual Values (Read Only Non-Volatile) (4 modules)
21EE
...Repeated for module number 2
Breaker Arcing Current Actual Values (Read Only Non-Volatile) (4 modules)
21F0
...Repeated for module number 2
Breaker Arcing Current Actual Values (Read Only Non-Volatile) (4 modules)
21F2
...Repeated for module number 2
Breaker Arcing Current Actual Values (Read Only Non-Volatile) (4 modules)
21FA
...Repeated for module number 3
21FE
...Repeated for module number 4
Breaker Arcing Current Commands (Read/Write Command) (4 modules)
2224
Breaker 1 Arcing Current Clear Command
2225
Breaker 2 Arcing Current Clear Command
2226
Breaker 3 Arcing Current Clear Command
2227
Breaker 4 Arcing Current Clear Command
Passwords Unauthorized Access (Read/Write Command)
2230
Reset Unauthorized Access
Transformer Differential and Restraint (Read Only)
2300
Transformer Reference Winding
2301
Transformer Differential Phasor Iad Magnitude
2302
Transformer Differential Phasor Iad Angle
2303
Transformer Restraint Phasor Iar Magnitude
2304
Transformer Restraint Phasor Iar Angle
2305
Transformer Differential 2nd Harm Iad Magnitude
2306
Transformer Differential 2nd Harm Iad Angle
2307
Transformer Differential 5th Harm Iad Magnitude
GE Multilin
RANGE
0 to 5
0 to 6
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 1.5
0 to 100000
0 to 1.5
0 to 65.535
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 1
0 to 2
---
0 to 99999999
0 to 99999999
0 to 99999999
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
1 to 6
0 to 30
-359.9 to 0
0 to 30
-359.9 to 0
0 to 999.9
-359.9 to 0
0 to 999.9
T60 Transformer Protection System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F167
---
1
F211
---
1
F300
---
1
F300
---
1
F300
pu
0.001
F001
V
1
F060
pu
0.001
F001
s
0.001
F001
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F102
---
1
F109
---
---
F001
2
kA
-cyc
1
F060
2
kA
-cyc
1
F060
2
kA
-cyc
1
F060
ms
1
F001
ms
1
F001
ms
1
F001
ms
1
F001
---
1
F126
---
1
F126
---
1
F126
---
1
F126
---
1
F126
---
1
F001
pu
0.001
F001
degrees
0.1
F002
pu
0.001
F001
degrees
0.1
F002
% fo
0.1
F001
degrees
0.1
F002
% fo
0.1
F001
DEFAULT
0 (SRC 1)
0 (None)
0
0
0
B
850
1000
600
100
0
0
0
0
0 (Disabled)
0 (Self-Reset)
0
0
0
0
0
0
0
0
0 (No)
0 (No)
0 (No)
0 (No)
0 (No)
1
0
0
0
0
0
0
0
B-19

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents