APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 55 of 73)
ADDR
REGISTER NAME
B0E6
IEC 61850 MMXU VAr.phsB Deadband 1
B0E8
IEC 61850 MMXU VAr.phsC Deadband 1
B0EA
IEC 61850 MMXU VA.phsA Deadband 1
B0EC
IEC 61850 MMXU VA.phsB Deadband 1
B0EE
IEC 61850 MMXU VA.phsC Deadband 1
B0F0
IEC 61850 MMXU PF.phsA Deadband 1
B0F2
IEC 61850 MMXU PF.phsB Deadband 1
B0F4
IEC 61850 MMXU PF.phsC Deadband 1
B0F6
...Repeated for Deadband 2
B12C
...Repeated for Deadband 3
B162
...Repeated for Deadband 4
B198
...Repeated for Deadband 5
B1CE
...Repeated for Deadband 6
IEC 61850 Received Analogs (Read Only) (32 modules)
B210
IEC 61850 Received Analog 1
B212
...Repeated for Received Analog 2
B214
...Repeated for Received Analog 3
B216
...Repeated for Received Analog 4
B218
...Repeated for Received Analog 5
B21A
...Repeated for Received Analog 6
B21C
...Repeated for Received Analog 7
B21E
...Repeated for Received Analog 8
B220
...Repeated for Received Analog 9
B222
...Repeated for Received Analog 10
B224
...Repeated for Received Analog 11
B226
...Repeated for Received Analog 12
B228
...Repeated for Received Analog 13
B22A
...Repeated for Received Analog 14
B22C
...Repeated for Received Analog 15
B22E
...Repeated for Received Analog 16
B230
...Repeated for Received Analog 17
B232
...Repeated for Received Analog 18
B234
...Repeated for Received Analog 19
B236
...Repeated for Received Analog 20
B238
...Repeated for Received Analog 21
B23A
...Repeated for Received Analog 22
B23C
...Repeated for Received Analog 23
B23E
...Repeated for Received Analog 24
B240
...Repeated for Received Analog 25
B242
...Repeated for Received Analog 26
B244
...Repeated for Received Analog 27
B246
...Repeated for Received Analog 28
B248
...Repeated for Received Analog 29
B24A
...Repeated for Received Analog 30
B24C
...Repeated for Received Analog 31
B24E
...Repeated for Received Analog 32
IEC 61850 Configurable Report Settings (Read/Write Setting)
B290
IEC 61850 Configurable Reports Dataset Items (64 items)
IEC 61850 XSWI Configuration (Read/Write Setting) (24 modules)
B370
FlexLogic Operand for IEC 61850 XSWI.ST.Loc Status
B373
...Repeated for module number 2
B376
...Repeated for module number 3
B379
...Repeated for module number 4
GE Multilin
RANGE
0.001 to 100
0.001 to 100
0.001 to 100
0.001 to 100
0.001 to 100
0.001 to 100
0.001 to 100
0.001 to 100
-1000000000000 to
1000000000000
0 to 848
0 to 4294967295
T60 Transformer Protection System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
---
0.001
F060
---
1
F615
---
1
F300
DEFAULT
10000
10000
10000
10000
10000
B
10000
10000
10000
0
0 (None)
0
B-63