B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 62 of 73)
ADDR
REGISTER NAME
C3F0
...Repeated for Virtual Output 89
C3F8
...Repeated for Virtual Output 90
C400
...Repeated for Virtual Output 91
C408
...Repeated for Virtual Output 92
C410
...Repeated for Virtual Output 93
B
C418
...Repeated for Virtual Output 94
C420
...Repeated for Virtual Output 95
C428
...Repeated for Virtual Output 96
Mandatory (Read/Write Setting or Command)
C430
Test Mode Function
C431
Force VFD and LED
C432
Test Mode Initiate
Clear Commands (Read/Write)
C434
Clear All Relay Records Command
Mandatory (Read Only)
C435
DSP Advanced Diagnostics Active
C436
Synchrophasor Feature Active
Mandatory (Read/Write Command)
C437
Relay Reboot Command
C438
Save Volatile Data
Clear Records (Read/Write Setting)
C446
Clear Demand Operand
C452
Clear User Fault Reports Operand
C454
Clear Event Records Operand
C456
Clear Oscillography Operand
C458
Clear Data Logger Operand
C45A
Clear Breaker 1 Arcing Current Operand
C45C
Clear Breaker 2 Arcing Current Operand
C45E
Clear Breaker 3 Arcing Current Operand
C460
Clear Breaker 4 Arcing Current Operand
C468
Clear Energy Operand
C46C
Clear Unauthorized Access Operand
C470
Clear Platform Direct Input/Output Statistics Operand
C472
Reserved (13 items)
Platform Direct Outputs (Read/Write Setting) (32 modules)
C600
Direct Output 1 Operand
C602
Direct Output 1 Events
C603
...Repeated for Direct Output 2
C606
...Repeated for Direct Output 3
C609
...Repeated for Direct Output 4
C60C
...Repeated for Direct Output 5
C60F
...Repeated for Direct Output 6
C612
...Repeated for Direct Output 7
C615
...Repeated for Direct Output 8
C618
...Repeated for Direct Output 9
C61B
...Repeated for Direct Output 10
C61E
...Repeated for Direct Output 11
C621
...Repeated for Direct Output 12
C624
...Repeated for Direct Output 13
C627
...Repeated for Direct Output 14
C62A
...Repeated for Direct Output 15
C62D
...Repeated for Direct Output 16
C630
...Repeated for Direct Output 17
C633
...Repeated for Direct Output 18
B-70
RANGE
0 to 2
0 to 1
0 to 4294967295
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
---
0 to 4294967295
0 to 1
T60 Transformer Protection System
APPENDIX B
UNITS
STEP
FORMAT
---
1
F245
---
1
F126
---
1
F300
---
1
F126
--
1
F126
--
1
F126
---
1
F126
---
1
F126
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
---
F001
---
1
F300
---
1
F102
DEFAULT
0 (Disabled)
0 (No)
1
0 (No)
0 (No)
0 (No)
0 (No)
0 (No)
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0 (Disabled)
GE Multilin

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents